Download  Print this page

Advertisement

Table 6.3 Error Code List for AnUCPU (Continue)
Error
Error
Code
Massage
(D9008)
"OPERATI
50
ON
ERROR"
(Checked
at
execution
of
instruction.)
Detailed
CPU
Error
Code
States
(D9091)
506
Stop or
Head I/O number
Continu
specified by the
e (set
by
parame
ter)
instructions is not of a
special function
module.
507
(1) When the AD57(S1)
(2) When an AD57(S1)
508
A CC-Link dedicated
command was issued to
three or more CC-Link
modules.
132
Error and Cause
LEDA/B RFRP
,
LEDA/B RTOP
RFRP ,
RTOP
or AD58 was
executing
instructions in
divided processing
mode, other
instructions were
executed to either of
them.
or AD58 was
executing
instructions in
divided processing
mode, other
instructions were
executed in divided
mode to another
AD57(S1) or AD58.
Corrective Action
Read the error step
using a peripheral
device and check and
correct program of the
step.
Read the error step
using a peripheral
device and provide
interlock with special
relay M9066 or modify
program structure so
that, when the AD57(S1)
or AD58 is executing
instructions in divided
processing mode, other
instructions may not be
executed to either of
them or to another
AD57(S1) or AD58 in
divided mode.
The CC-Link dedicated
command can be issued
only to two or less
CC-Link modules.