Table 6.1 Error Code List for AnNCPU (Continue)
Error
Error
Code
Message
(D9008)
"CHK
14
FORMAT
ERR"
(Checked at
STOP/PAUS
E→RUN)
CPU
Error and Cause
States
Stop
(1) Instructions (including
NOP ) except LD X ,
LDI X , AND X
ANI X
are included in
the
CHK
circuit block.
(2) Multiple
instructions are given.
(3) The number of contact
points in the
instruction circuit block
exceeds 150.
(4) There is no
circuit block before the
CHK
instruction
circuit block.
(5) The device number of
D1 of the
instruction is different
from that of the contact
point before the
CJ P
(6) Pointer P254 is not
given to the head of the
CHK
instruction
circuit block.
P254
86
Check the program in the
CHK
and
block according to items (1)
to (6) in the left column.
Correct problem using the
instruction
peripheral and perform
operation again.
CHK
CHK
CJ P
CHK D1 D2
instruction.
CHK D1 D2
Corrective Action