Table 6.2 Error Code List for AnACPU (Continue)
Error
Error
Code
Massage
(D9008)
"MISSING
12
END INS"
(Checked
at STOP →
RUN.)
"CAN'T
13
EXECUTE
(P)"
(Checked
at
execution
of
instruction.)
Detailed
Error
CPU
Code
States
(D9091)
121
STOP
The
( FEND ) instruction is
not given in the main
program.
122
The
( FEND ) instruction is
not given in the sub
program if the sub
program is set by
parameters.
131
STOP
The same device
number is used at two
or more steps for the
pointers (P) and
interrupt pointers (I)
used as labels to be
specified at the head of
jump destination.
132
Label of the pointer (P)
specified in the
LEDA/B FCALL
LEDA/B BREAK
instruction is not
provided before the
Error and Cause
END
END
CJ ,
SCJ ,
CALL ,
CALLP ,
JMP ,
or
END
instruction.
96
Corrective Action
Write the
END
instruction at the end of
the main program.
Write the
END
instruction at the end of
the sub program.
Eliminate the same
pointer numbers
provided at the head of
jump destination.
Read the error step
using a peripheral
device, check contents
and insert a jump
destination pointer (P).