Table 6.1 Error Code List for AnNCPU (Continue)
Error
Error
Code
Message
(D9008)
"MISSING
12
END INS."
(Checked at
STOP →
RUN)
"CAN'T
13
EXECUTE(P)
" (Checked at
the
execution of
instruction)
CPU
Error and Cause
States
Stop
(1) There is no
( FEND ) instruction in
the program.
(2) When subprogram has
been set by the
parameter, there is no
END
instruction in
the subprogram.
Stop
(1) There is no jump
destination or multiple
destinations specified by
the
CJ ,
CALL ,
JMP
instruction.
(2) There is a
instruction and no
setting of subprogram.
(3) Although there is no
CALL
RET
instruction
exists in the program
and has been executed.
(4) The
CJ ,
CALL ,
JMP
instruction has
been executed with its
jump destination located
below the
instruction.
84
Corrective Action
END
Write
at the end of program.
Read the error step by use
of peripheral equipment and
correct the program at that
step.
SCJ ,
(Insert a jump destination or
CALLP , or
reduce multiple destinations
to one.
CHG
instruction, the
SCJ ,
CALL P , or
END
END
instruction