3.4 Mechanical Specifications

Dimensions: 8.3 x 4.3 x 2.4" (211 x 108 x 60mm)
Weight: 1.94 lbs (880g)
Shock and Vibration: per EN 61010-1
Tightness: IP 54 per EN 60529 (electrical IP2X for the terminals)

3.5 Environmental Specifications

Operating Temperature: 32° to 122°F (0° to 50°C)
Storage Temperature (<30 days): -4° to +122°F (-20 to +50°C) with batteries
Recharging Temperature: 50° to 104°F (10° to 40°C)
Altitude: Operating: 0 to 2000 meters (6560 ft)
Non-Operating: 0 to 10,000 meters (32800 ft)
Operating Relative Humidity: 10 to 85%

3.6 Safety Specifications

Electrical Safety
600V CAT III, Pollution Degree 2
EN 61010-31: 2002
EN 61010-1: 2001
EN 61010-2: 1995
Electromagnetic Compatibility
Immunity: EN 61236-1 A2
Emission: EN 61236-1 A2
Electrostatic discharges: IEC 1000-4-2
Radiation field resistance: IEC 1000-4-3
Fast transients resistance: IEC 1000-4-4
Electric shock resistance: IEC 1000-4-5
Conducted RF interference: IEC 1000-4-6
Interruption of Voltage: IEC 1000-4-11