Power Supply - AEMC 8230 User Manual

Powerpad jr. single-phase power quality analyzer
Table of Contents

Advertisement

Nominal Range
Measurement Range
Probe Output Signal*
Sensor
Safety
*Output is proportional to the amplitude and frequency of the measured current.
NOTE: Currents <10A will be displayed as zero. Neutral current measures down to 0A.
Nominal Range
Measurement Range
Probe Output Signal*
Sensor
Safety
3.2.6

Power Supply

AC Power (internal power supply)
Operating Range: 120V ± 10% @ 60Hz ; 230V ± 10% @ 50Hz (model dependent)
Max Power: 23.7VA
Power Source
(allows use in the event of an interruption)
Type: 6 NiMH rechargeable battery pack (IEC LR6 - NEDA 15A) >1800mAh
Rated Voltage: 7.2V
Charging Current: 0.6 to 0.8A
Charge Time: 4 hrs (NiMH)
Battery Life: >8 hrs with display on
NOTE: The battery starts to charge when the power cord is connected. When the
battery is charged, the instrument uses the current supplied by the power supply,
without drawing from the battery.
18
AmpFlex
3000A
AC
10A to 6500A
140mV
/3000A
AC
Length = 24" (610mm); Ø = 7.64" (190mm)
Length = 36" (910mm); Ø = 11.46" (290mm)
EN 61010-2-032, Pollution Degree 2, 600V CAT IV, 1000V CAT III
MiniFlex
1000A
AC
10A to 1000A
47µV
/1000A
AC
Length = 10" (250mm); Ø = 2.75" (70mm)
EN 61010-2-032, Pollution Degree 2, 600V CAT IV, 1000V CAT III
≥ 40 hrs with display off (recording mode)
At least 300 charging/discharging cycles
Sensors
®
AC
at 60Hz
AC
Sensors
®
AC
at 60Hz
AC
Power Quality Analyzer Model 8230