Table 1: Notice - Electrical Safety Specifications - Redline RDL-3000 Installation Manuallines

Radio platform
Hide thumbs Also See for RDL-3000:
Table of Contents

Advertisement

RDL-3000
Cet appareil est raccordée à une source de tension de –36 a -57 VCD, qui doit être
isolée de toute autre source de tension et raccordée à une mise à terre isolée. Les
produits de Redline ne doivent pas être installés près de ligne à haute tension. Des
dommages corporels sévères et même la mort peuvent survenir si l'antenne ou toute
autre pièce viennent en contact avec des lignes de haute tension Dommage corporel.
Radio Frequency Safety / Sécurité des Fréquences Radio
The installer of this radio equipment must ensure that the antenna is located or pointed
such that it does not emit RF fields in excess of the general population limits as defined
by FCC CFR 47, Part 2.1091, Radiofrequency radiation exposure evaluation for fixed
devices & Health Canada limits for the general population; consult Safety Code 6,
obtainable from Health Canada's website:
http://www.hc-sc.gc.ca/ewh-semt/pubs/radiation/radio_guide-lignes_direct-eng.php
Le programme d'installation de cet équipement radio doit s'assurer que l'antenne est
située ou orientée de façon à ne pas émettre des champs RF au-delà de la population
en général des limites telles que définies par la FCC CFR 47, partie 2,1091, l'évaluation
par radiofréquence exposition aux rayonnements pour les appareils fixes et de Santé
Canada limites pour la population en général, consulter le Code de sécurité 6, disponible
sur site Web de Santé Canada:
http://www.hc-sc.gc.ca/ewh-semt/pubs/radiation/radio_guide-lignes_direct-fra.php
Personal Safety
WARNING: HOT SURFACE. DO NOT TOUCH.
The Elte-MT radio platform is rated for operation at extreme ambient temperatures.
When operating in high temperature conditions, the chassis surface area can be higher
than the ambient temperature and personal thermal protection should be employed for
any maintenance or inspection activity.
Electrical Safety
The equipment meets the requirements for class I EN 60950 (protection against electric
shock).
All external circuits are TNV-1 (as defined in EN 60950).
All equipment must be grounded before the power cable is connected.
For electrical safety the DC power supply shall have reinforced insulation to the
mains supply.
Electrical Safety Compliance / Conformité à la Sécurité Electrique
The RDL-3000 hardware has been tested for compliance to the electrical safety
specifications listed in the following table:
Class I
All External Circuits
All equipment must be grounded
70-00159-01-06
INSTALLATION GUIDELINES
Attention au personnel du service: 48V CD

Table 1: Notice - Electrical safety specifications

Proprietary Redline Communications © 2012
EN 60950
TNV-1 as defined in EN 60950
Page
10
of 65
.
.
kune 12, 2012

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents