RDL-3000
5.4

Ethernet Port

This section describes installation and weatherproofing of the outdoor Ethernet cable.
Note: The PoE does not amplify the Ethernet signal. The maximum total length of the
Ethernet cable is 91.5 m (300 ft). For example, 90 m (295 ft) from the RDL-3000 to the
PoE and 1.5 m (5 ft) from the PoE to the local network equipment.
5.4.1

Ethernet Cable Connections

The Redline outdoor Ethernet cable is terminated with a non-hooded RJ-45 connector.
This connects to the mating RJ-45 connector located inside the RDL-3000 enclosure.
When connecting the outdoor Ethernet cable to the RDL-3000, ensure the RJ-45 plug is
fully inserted and locked into the socket.
When inserting the RJ-45 plug into the mating socket, you should hear an audible click
from the locking mechanism. Ensure the connector is locked before sealing and
weatherproofing the RDL-3000 Ethernet port.

Assembling the Ethernet Weatheproof Connector

The Ethernet port is protected by a weatherproof connector. The Ethernet cable must be
threaded through the connector components and the connector and re-assembled.
When assembled correctly, the Ethernet port seal is water-resistant.
Figure 27: Procedures - Ethernet Port - Weatherproof Connector Assembly
Use the following steps to connect the Ethernet cable to the RDL-3000 unit.
1. Remove the large threaded nut (4) and split rubberized gasket (3) from the RDL-
3000 Ethernet port.
2. Thread the Ethernet cable (5) through the large nut. The threaded end of the nut (4)
must be oriented towards the connector end of the Ethernet cable.
3. Fit the split rubberized gasket (3) over the Ethernet cable (5) about 150 mm (6 in)
from the end of the cable. The larger end of the gasket must be oriented towards the
connector end of the Ethernet cable.
4. Fit the split metal washer (2) over the Ethernet cable (5) about 150 mm (6 in) from
the end of the cable and position against the rubberized gasket.
5. Connect the RJ-45 connector (1) to the mating connector on the RDL-3000. This
connector is located inside the Ethernet port opening.
6. Slide the split rubberized gasket and metal washer along the Ethernet cable and
position tightly against the RDL-3000 port.
70-00159-01-06
INSTALLATION GUIDELINES
Proprietary Redline Communications © 2012
Drawing
Page
39
of 65
kune 12, 2012