RDL-3000

Long Reset

If the IP address, username or password of the RDL-3000 is unknown, use the 'long
reset' procedure to access the Web or Telnet interface: Refer to the RDL-3000 Users
Guide for a detailed description or this operation.
1. Power-cycle the unit on for 10 seconds, off for 5 seconds, and then on.
2. Wait 75 to 80 seconds and then use a browser or Telnet to login. Use the default user
account 'admin' and password 'admin'.
3. Modify settings as required and reboot the RDL-3000 to restore normal operation.
5.5.3

Step 3: Install Options Key

Options keys (a string of numbers, letters, and dashes) enable RDL-3000 features
including the maximum uncoded burst rate (UBR) and frequency ranges. Options keys
are encoded based MAC address, making each key unique to a specific RDL-3000. The
options key enables specific system parameters and must be entered before the RDL-
3000 can be fully configured.

Operation with No Options Key

Prior to installing an options key, the RDL-3000 will only operate in PMP SS mode
(subscriber). At a minimum, the operator must obtain and install at least one permanent
or temporary options key before it is possible to deploy and test a wireless link. For
example:
Parameter
Mode
Channel
UBR
DFS
Max PIR
VLAN Data
VLAN Mgmt
Encryption
RF Frequency
(MHz)

Enter Permanent Options Key

A permanent options key must be installed before the RDL-3000 is placed in-service.
Use a Web browser to login to the RDL-3000. You must login as administrator.
1.
Click Utilities ->
2.
Enter a valid permanent or temporary options key in the Options Key 1 field.
3.
Click Activate to enable the new features (does not require reboot).
4.
Telnet may also be used to install an options key. Refer to the RDL-3000 User Manual
for a description of the commands.
70-00159-01-06
INSTALLATION GUIDELINES

Table 14: Procedures - Operation with No Options Key

Setting
PMP SS
10 MHz
3 Mbps
Permanently enabled
1 Mb/s
Disabled
Disabled
Disabled
T502: 3300-3800, 3650-3700, 4400-5000, 4940-4990,
*
5150-5250, 5495-5600, 5650-5725, 5725-5795,
5815-5850
Note: The factory default setting for Auto Scan is 'disabled'.