Operating
User
line
level
835
O
Mixing valve Xp
836
O
Mixing valve Tn
Floor curing function
Off ¦ Functional heating ¦ Curing heating
850
I
¦ Functional/ curing heating¦ Curing/fun-
ctional heating ¦ Manually
851
I
Floor curing setp manual
Excess heat draw
861
F
Off ¦ Heating mode ¦ Always
With buffer storage tank
870
F
No ¦ Yes
With primary controller / system pump
872
F
No ¦ Yes
882 (***)
F
Pump speed min
883 (***)
F
Pump speed max
Optg mode changeover
900
F
None ¦ Protection ¦ Reduced ¦ Comfort ¦
Automatic
Cooling circuit 1
Operating mode
901 (**)
E
Off ¦ Automatic
902 (**)
E
Comfort cooling setpoint
release
907 (**)
E
24h/day ¦ Time programs HCs ¦ Time
program 5
908 (**)
I
Flow setpoint at OT 25°C
909 (**)
I
Flow setpoint at OT 35°C
912 (**)
I
Cooling limit at OT (outside temperature)
913 (**)
F
Locking period at end of heating
918 (**)
F
Start of summer compensation at OT
919 (**)
F
End of summer compensation at OT
Summer compensation setpoint incre-
920 (*)
F
ase
923 (**)
I
Flow setpoint min. OT 25°C
924 (**)
I
Flow setpoint min. OT 35°C
928 (**)
F
Room influence
932 (**)
F
Room temp limitation
938 (**)
F
Mixing valve subcooling
Actuator type
939 (**)
F
2-position ¦ 3-position
940 (**)
F
Switching differential 2-pos
941 (**)
F
Actuator running time
942 (**)
O
Mixing valve Xp
943 (**)
O
Mixing valve Tn
Mixing valve in heating mode
945 (**)
F
Control ¦ Open
946 (**)
F
Dewpt monitor locking time
947 (**)
F
Flow setpt increase hygro
948 (**)
F
Start flow increase at R.H.
950 (**)
I
Flow temp diff dewpoint
With buffer storage tank
962 (**)
F
No ¦ Yes
With primary controller / system pump
963 (**)
F
No ¦ Yes
E=End user I=Commissioning F=Heating engineer O=OEM BZ=Operating line
(*) QAA75../78.. only, (**) RVS43.. only, (***) RVS63..
Function
87
Default value
Min
32
1
120
10
Off
25
0
Always
Yes
Yes
100
0
100
0
Protection mode
Automatically
24.0
15
24 h/day
20
8
16
8
20
− − − / 8
24
− − − / 8
26
20
35
20
4
− − − / 1
18
8
18
8
80
− − − / 1
0.5
− − − / 0.5
0
0
3-position
2
0
120
30
12
1
90
10
Controls
60
− − − / 10
3
− − − / 1
60
0
2
− − − / 0
No
No
THECNICAL ASSISTANCE SERVICE
Range
Unit
Range
Max
100
°C
873
s
-
95
°C
-
-
-
100
%
100
%
-
-
40
°C
-
35
°C
38
355
°C
100
h
35
°C
35
°C
10
°C
35
°C
35
°C
10
°C
4
°C
20
°C
20
°C
873
s
100
°C
873
s
600
min
10
°C
100
%
10
°C