Draining The Condensate; Installing The Room Unit - Riello ALUDOMUS SOLAR KV/200 20 ISC SOLAR Installation And Maintenance Manual

Hide thumbs Also See for ALUDOMUS SOLAR KV/200 20 ISC SOLAR:
Table of Contents

Advertisement

INSTALLER

2 .8 Draining the condensate

9
Always maintain a slope "i" of over 3° and ensure
that the diameter of any hose used is greater than
that of the boiler's own condensate drain pipe.
9
The connection to the waste water drain pit must
be made in compliance with national and local le-
gislation and standards.
9
Condensate from the boiler and that from the flue
stack should be channelled to the same drain pit.
9
The surface on which the boiler stands must be
perfectly horizontal and flat over the entire area of
the boiler frame in order to avoid condensate drai-
nage problems.
9
Any condensate neutralisation units deemed ne-
cessary may be connected downstream from the
siphon. Evaluate the neutralisation unit after one
year of operation to estimate the duration of the
neutralisation charge. The total duration of the
charge can be estimated from the level after one
year.

2 . 9 Installing the room unit

9
See the "Electrical connections" section.
1
2
38
i≥3°
i
BOILER
Condensate
from boiler
Condensate from stack
To drain or
neutralisation
unit if installed
3
4
Flue
Drain
5