ERROR TABLE
Error
Diagnostic
code via
info
QAA
0
0
0
473
10
150
perature sensor
10
151
perature sensor
20
142
20
143
20
405
20
406
20
410
20
411
20
412
20
413
Flue gas sensor
28
152
Flue gas sensor
28
153
Flue gas sensor
28
507
CH flow sensor 2
32
524
CH flow sensor 2
32
525
CH flow sensor 2
32
546
CH flow sensor 2
32
547
CH return sensor
40
144
CH return sensor
40
145
CH return sensor
40
407
CH return sensor
40
408
Description of
Type of fault
error
No input code
No input code
No input code
No input code
Outdoor tem-
Short circuit in outdoor
temperature sensor
error
Outdoor tem-
Outdoor temperature
sensor faulty
error
Boiler sensor 1
Short circuit in tempera-
error
ture sensor B2
Boiler sensor 1
Temperature sensor B2
error
Boiler sensor 1
Boiler sensor 1 error
error
Boiler sensor 1
Boiler sensor 1 error
error
Boiler sensor 1
Short circuit in tempera-
error
ture sensor B2
Boiler sensor 1
Temperature sensor B2
error
Boiler sensor 1
No further differentiation
error
Boiler sensor 1
No further differentiation
error
Short circuit in tempera-
error
ture sensor
Temperature sensor
error
Temperature reading not
error
plausible
Short circuit in CH 2 tem-
error
perature sensor
CH 2 temperature sensor
error
Short circuit in additional
zone clip-in temperature
error
sensor (accessory)
Additional zone clip-in
temperature sensor faul-
error
ty (accessory)
Short circuit in return
1 error
temperature sensor (B7)
Return temperature sen-
1 error
sor (B7) faulty
No further differentiation
1 error
No further differentiation
1 error
System action
-
Message
Message
Message
Safety shutdown
Safety shutdown
faulty
Safety shutdown
Safety shutdown
Burner lockout
(permanent).
Lockout reset re-
quired
Burner lockout
(permanent).
faulty
Lockout reset re-
quired
Burner lockout
(permanent).
Lockout reset re-
quired
Burner lockout
(permanent).
Lockout reset re-
quired
Message
Message
faulty
Safety shutdown
Message
Message
faulty
Message
Message
Safety shutdown
Safety shutdown
Safety shutdown
Safety shutdown
67
THECNICAL ASSISTANCE SERVICE
Procedure
-
-
Check/replace
outdoor temperature
sensor
Check/replace
outdoor temperature
sensor
Check/replace tem-
perature sensor
Check/replace tem-
perature sensor
Check/replace tem-
perature sensor
Check/replace tem-
perature sensor
Check/replace tem-
perature sensor
Check/replace tem-
perature sensor
Check/replace tem-
perature sensor
Check/replace tem-
perature sensor
Check/replace flue
gas temperature
sensor
Check/replace flue
gas temperature
sensor
Check/replace flue
gas temperature
sensor
Check/replace tem-
perature sensor
Check/replace tem-
perature sensor
Check/replace tem-
perature sensor
Check/replace tem-
perature sensor
Check/replace tem-
perature sensor
Check/replace tem-
perature sensor
Check/replace tem-
perature sensor
Check/replace tem-
perature sensor