THECNICAL ASSISTANCE SERVICE
Error
Diagnostic
code via
info
QAA
154
426
154
427
154
433
154
434
154
435
154
474
154
475
154
476
154
477
154
478
154
479
154
498
160
83
160
281
Description of
Type of fault
error
Boiler temperature has
risen more quickly than
Generic error
permitted by parameter
TempGradMax
The reset criterion for
error 426 has not been
reached (criterion: boiler
Generic error
temperature < boi-
ler setpoint and dT <
dTkTrSTB)
Generic error
dT is > dTkTrSTB + 16K
The reset criterion for
error 433 has not been
Generic error
reached (criterion: dT <
½ dTkTrSTB)
Error 433 has occurred
more times than per-
Generic error
mitted by the burner
parameter GrenzeDeltaT
The DHW setpoint for HMI
Generic error
is < TbwSmin
The DHW setpoint for HMI
Generic error
is > TbwSmax
HMI flow temperature is
Generic error
< TkSmin
HMI flow temperature is
Generic error
> TkSnorm
HMI room temperature
Generic error
setpoint is < TrSim
HMI room temperature
Generic error
setpoint is > TrSim
Water schematic with CH
Generic error
circuit 2 and room unit
unavailable
The acceptable speed
Fan speed
range for starting the
threshold not
ignition sequence was
reached
not reached during start-
Fan speed is below re-
Fan speed
quired threshold, phase
threshold not
Ph_TLO: (N_TL-N_TH_Del-
reached
ta), phase Ph_TNN: NoG_
System action
Safety shutdown
Safety shutdown
Safety shutdown
Safety shutdown
Burner lockout
(permanent).
Lockout reset re-
quired
Message
Message
Message
Message
Message
Message
Message
Burner lockout
(permanent).
Lockout reset re-
quired
up
Burner lockout
(permanent).
Lockout reset re-
quired
Null.
74
Procedure
OEM parameter not
editable via QAA.
Generic error. Check
the system. Boiler
temperature rises too
quickly
OEM parameter not
editable via QAA.
Generic error. Check
the system. Boiler
temperature rises too
quickly
OEM parameter not
editable via QAA. Ge-
neric error. Check the
system. The tempe-
rature differential in
the boiler is excessive
OEM parameter not
editable via QAA. Ge-
neric error. Check the
system. The tempe-
rature differential in
the boiler is excessive
OEM parameter not
editable via QAA. Ge-
neric error. Check the
system. The tempe-
rature differential in
the boiler is excessive
OEM parameter 508,
editable via pas-
sword. Check the
DHW system; tempe-
rature too low
OEM parameter 508,
editable via pas-
sword. Check the
DHW system; tempe-
rature too low
Installer parameter
503. Check system,
boiler setpoint
Installer parameter
505. Check system,
boiler setpoint
Installer parameter
501. Check system,
zone setpoint
Installer parameter
501. Check system,
zone setpoint
Check HMI program-
ming
Contact Technical
Assistance Service
OEM parameter not
editable via QAA. Fan
differentials excee-
ded. Contact Techni-
cal Assistance Service