TWIN FLUES (Ø 80)
Twin flues can be oriented in whatever direction is most
convenient for the room.
The table below shows permitted pipe lengths (straight
line).
9
Joints must be sealed using materials capable of
withstanding temperatures of at least 250°C (e.g.
filler, mastic or silicon based sealant).
9
Maximum straight length is the maximum length of
the flue without bends, terminals or joints.
C33
C43
C13
C13
B23
Upstream fan. Comburent air intake directly
from the room where the boiler is installed. Flue
gas vent via horizontal or vertical flues, with air
ventilation to room.
B23P As B23 but with flue gas vent designed to opera-
te at positive pressure.
B53
Upstream fan. Comburent air intake directly
from the room where the boiler is installed. Flue
gas venting via dedicated pipes. Air ventilation
to room.
B53P As B53 but with dedicated flue gas vent desig-
ned to operate at positive pressure.
C13
Concentric wall vent. Twin flue pipes can also be
used, but the wall through-pipes must be con-
centric or located close enough to be subjected
to similar wind conditions.
C33
Concentric roof vent. Outlets as for C13.
C43
Vent and air intake via shared twin pipes,
subjected to similar wind conditions.
C53
Separate wall or roof vent and air intake, in are-
as of different pressure but never on opposite
walls.
C63
Upstream fan. Comburent air intake and flue
gas vent without flue terminals (configuration
not permitted in Belgium).
9
In Italy, refer to DPR 412 and UNI CIG 7129 standard
TWIN VENT AND AIR INLET
Flue gas vent Ø 80 mm
Air inlet Ø 80 mm
Maximum length of pipes
(air inlet +
flue gas vent) (m)
26
43
INSTALLER
Pressure drop (m)
45° bend
45° bend
0,5
1