Operating
User
line
level
Function of input H2
Optg mode changeover HCs + DHW ¦
Optg mode changeover HCs ¦ Optg mode
changeover HC1 ¦ Optg mode changeover
HC2 ¦ Optg mode changeover HCP ¦ Heat
generation lock ¦ Error/alarm message
¦ Min flow temp setpoint ¦ Excess heat
6046
I
discharge ¦ Swimming pool enable ¦
Dewpoint monitor (**) ¦ Flow temp. setpt
increase, hygro (**) ¦ Refrig request (**) ¦
Heat request 10V ¦ Refrig. request 10V (**)
¦ Pressure measurement 10V ¦ Rel. room
humidity 10V (**) ¦ Room temperature
10V (**)
Contact type H2
6047
I
NC ¦ NO
6048 (**)
I
Function value, contact H2
6048(***)
I
Min flow temp setpoint H2
6049 (**)
I
Voltage value 1, H2
6050 (**)
I
Function value 1, H2
6050 (***)
I
Temp value 10V H2
6051 (**)
I
Voltage value 2, H2
6052 (**)
I
Function value 2, H2
6052 (***)
I
Pressure value 3.5V H2
Function output UX
None ¦ Boiler pump Q1 ¦ DHW pump Q3
¦ DHW interm circ pump Q33 ¦ Heat circ
pump HC1 Q2 ¦ Heat circ pump HC2 Q6
6070 (***)
I
¦ Heat circ pump HCP Q20 ¦ Collector
pump Q5 ¦ Solar pump ext exch K9 ¦
Solar pump buffer K8 ¦ Solar pump swi
pool K18 ¦ Collector pump 2 Q16 ¦ Boiler
setpoint ¦ Output setpoint ¦ Heat request
Signal logic output UX
6071 (***)
I
Standard ¦ Inverted
6075 (***)
I
Temperature value 10V UX
Sensor type collector
6097
F
NTC 10k ¦ Platinum 1000
6098
F
Readjustm collector sensor
6099
F
Readjustm coll sensor 2
6100
F
Readjustm outside sensor
Sensor type flue gas temp
6101
F
NTC 10k ¦ Platinum 1000
6102
F
Readjustm flue gas sensor
6110
F
Time constant building
6112
O
Gradient room model
6116 (**)
O
Time constant setp compens
6117
O
Central setp compensation
Setpoint drop
6118 (**)
O
delay
Frost protection for the plant
6120
F
Off ¦ On
6128
F
Heat request below OT
6129
F
Heat request above OT
Heat req in economy mode
6131
F
Off ¦ On DHW ¦ On
E=End user I=Commissioning F=Heating engineer O=OEM BZ=Operating line
(*) QAA75../78.. only, (**) RVS43.. only, (***) RVS63..
Function
Optg mode chan-
101
Default value
Min
geover HCs+DHW
NO
70
8
70
8
0
0
0
-100
100
5
10
0
70
-100
5.0
0.0
None
Standard
100
5
NTC 10k
0
-20
0
-20
0
-3.0
NTC 10k
0
-20
15
0
60
0
10
0
20
− − − / 1
60
− − − / 1
Off
− − − /
− − −
-50
− − − /
− − −
-50
Off
THECNICAL ASSISTANCE SERVICE
Range
Unit
Range
Max
130
°C
120
°C
10
Volt
500
-
130
°C
10
Volt
500
-
10.0
bar
130
°C
-
20
°C
20
°C
3.0
°C
-
20
°C
50
h
300
min/°C
14
min
100
°C
200
k/min
-
50
°C
50
°C