Riello ALUDOMUS SOLAR KV/200 20 ISC SOLAR Installation And Maintenance Manual page 48

Hide thumbs Also See for ALUDOMUS SOLAR KV/200 20 ISC SOLAR:
Table of Contents

Advertisement

THECNICAL ASSISTANCE SERVICE
T
Press the
− With an outdoor temperature sensor connected
you can now set the room temperature setpoint
− With no outdoor temperature sensor connected
you can now set the central heating circuit tem-
perature setpoint.
+ -
Press the
Press any of the
R T M V
The new setting is stored in memory.
S
− Press the
− Press the
setpoint.
Press any of the
R T M V
The new setting is stored in memory.
9
If an outdoor temperature sensor is installed, set
installer parameter "532 Heating curve slope hea-
ting circuit 1" as instructed in the section "Setting
functioning parameters".
9
If any boiler ignition or functioning errors are de-
tected, the display shows the type of error.
Errors can be of two types:
− PERMANENT errors are those that can only be
cancelled by pressing the
− TEMPORARY errors are those that are automati-
cally cancelled as soon as the cause is rectified
(see "Error codes").
9
If the safety thermostat trips, the PERMANENT "E110"
error appears on the display.
Proceed as follows to reset the safety thermostat:
− Wait until boiler temperature falls below 80°C
S
− Press the
− The complete ignition cycle will be repeated up
to the ignition of the flame.
9
Any additional central heating zones must be con-
figured using the room unit (refer also to the in-
struction manuals supplied with the various acces-
sory kits).
key:
keys to adjust the setpoint.
keys to exit.
key.
+ -
. keys to adjust the DHW
keys to exit.
S
key.
key.
48