Riello ALUDOMUS SOLAR KV/200 20 ISC SOLAR Installation And Maintenance Manual page 68

Hide thumbs Also See for ALUDOMUS SOLAR KV/200 20 ISC SOLAR:
Table of Contents

Advertisement

THECNICAL ASSISTANCE SERVICE
Error
Diagnostic
code via
info
QAA
40
414
40
415
40
416
40
417
50
146
50
147
50
462
52
148
52
149
61
126
61
382
61
383
61
384
61
385
61
386
61
387
61
471
61
472
62
438
73
609
Description of
Type of fault
error
CH return sensor
Short circuit in return
1 error
temperature sensor (B7)
CH return sensor
Return temperature sen-
1 error
sor (B7) faulty
CH return sensor
No further differentiation
1 error
CH return sensor
No further differentiation
1 error
DHW 1 tempera-
Short circuit in DHW tem-
ture sensor error
perature sensor (B3)
DHW 1 tempera-
DHW temperature sensor
ture sensor error
(B3) faulty
Short circuit and fault in
DHW 1 tempera-
DHW temperature sensor
ture sensor error
DHW 2 sensor
Short circuit in DHW tem-
error
perature sensor (B3)
DHW 2 sensor
DHW temperature sensor
error
(B3) faulty
Room unit 1 error No further differentiation
Room unit 1 error No further differentiation
Room unit 1 error No further differentiation
Room unit 1 error No further differentiation
Room unit 1 error
Software error detected
Room unit 1 error
Unknown message type
Room unit 1 error No further differentiation
Unknown datapoint re-
Room unit 1 error
quest from room unit
Room unit waiting to
Room unit 1 error
write to write-protected
parameter
Room unit 1 or
timer connection
Connection error
error
Solar collector
sensor error (if
Valid temperature for so-
solar clip-in
lar collector not available
option is installed
- accessory)
System action
Burner lockout
(permanent).
Lockout reset re-
quired
Burner lockout
(permanent).
Lockout reset re-
quired
Burner lockout
(permanent).
Lockout reset re-
quired
Burner lockout
(permanent).
Lockout reset re-
quired
Safety shutdown
Message
Message
(B3)
Message
Message
Message
Message
Message
Message
Message
Message
Message
Message
Message
Message
Message
68
Procedure
Check/replace tem-
perature sensor
Check/replace tem-
perature sensor
Check/replace tem-
perature sensor
Check/replace tem-
perature sensor
Check/replace tem-
perature sensor
Check/replace tem-
perature sensor
Check/replace tem-
perature sensor
Check/replace tem-
perature sensor
Check/replace tem-
perature sensor
Check/replace room
unit, room tempera-
ture sensor
Check/replace room
unit, room tempera-
ture sensor
Check/replace room
unit, room tempera-
ture sensor
Check/replace room
unit, room tempera-
ture sensor
Check/replace room
unit, room tempera-
ture sensor
Check/replace room
unit, room tempera-
ture sensor
Check/replace room
unit, room tempera-
ture sensor
Check/replace room
unit, room tempera-
ture sensor
Check/replace room
unit, room tempera-
ture sensor
Check connection
to room unit/timer-
thermostat. Unit not
recognised
Check solar clip-in;
check/replace tem-
perature sensor

Advertisement

Table of Contents
loading

Table of Contents