Error
Diagnostic
Description of
code via
info
QAA
77
156
sensor error (not
77
157
sensor error (not
Water pressure
78
154
sensor error (not
Water pressure
78
155
sensor error (not
Water pressure
78
510
sensor error (not
Water pressure
78
511
sensor error (not
LPB communica-
81
518
82
519
LPB address error
91
131
EEPROM data loss
91
258
EEPROM data loss
91
268
EEPROM data loss
91
583
EEPROM data loss
Electronic device
92
293
Electronic device
92
294
Electronic device
92
484
Electronic device
92
485
Electronic device
92
486
Electronic device
92
487
Electronic device
92
488
Electronic device
92
489
Electronic device
92
490
Type of fault
error
Air pressure
Short circuit in tempera-
ture sensor
used)
Air pressure
Pressure switch faulty
used)
Short circuit in pressure
switch
used)
Pressure switch faulty
used)
Water pressure too high
or too low, or reading
used)
not plausible
Reading not plausible
used)
LPB circuit short circuited
tion error
or not powered
LPB address conflict
Hardware fault
Data overflow caused
by power failure during
functioning
Hardware fault
EEPROM read/write test
error
Hardware error
errors
Hardware error
errors
Room thermostat input
errors
faulty
Air pressure switch input
errors
faulty
Gas pressure switch
errors
input faulty
Safety relay output faulty
errors
Safety valve output faulty
errors
DHW flow switch input
errors
faulty
CH flow switch input
errors
faulty
System action
Message
Message
Message
Message
Burner lockout
(permanent).
Lockout reset re-
quired
Safety shutdown
Message
Message
Burner lockout
(permanent).
Lockout reset re-
quired
Burner lockout
(permanent).
Lockout reset re-
quired
Burner lockout
(permanent).
Lockout reset re-
quired
Burner lockout
(permanent).
Lockout reset re-
quired
Burner lockout
(permanent).
Lockout reset re-
quired
Burner lockout
(permanent).
Lockout reset re-
quired
Message
Message
Message
Message
Message
Message
Message
69
THECNICAL ASSISTANCE SERVICE
Procedure
Check/replace air
pressure switch
Check/replace air
pressure switch
Check/replace water
pressure switch
Check/replace water
pressure switch
Check/replace water
pressure switch
Check/replace water
pressure switch
Check the LPB con-
nection. Check the
power supply to the
control card
Check the LPB con-
nection
Contact Technical
Assistance Service
Contact Technical
Assistance Service
Contact Technical
Assistance Service
Contact Technical
Assistance Service
Contact Technical
Assistance Service
Contact Technical
Assistance Service
Contact Technical
Assistance Service
Contact Technical
Assistance Service
Contact Technical
Assistance Service
Contact Technical
Assistance Service
Contact Technical
Assistance Service
Contact Technical
Assistance Service
Contact Technical
Assistance Service