ALUDOMUS SOLAR KV/200 20 ISC SOLAR
EN USER MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Riello ALUDOMUS SOLAR KV/200 20 ISC SOLAR

  • Page 1 ALUDOMUS SOLAR KV/200 20 ISC SOLAR EN USER MANUAL...
  • Page 2: Table Of Contents

    ENd USER CONTENTS Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 General safety information .
  • Page 3 Technical Assistance Centres also stock any original spare parts that might be required. This instruction manual contains important instructions and precautions that must be observed to ensure the trou- ble-free installation and efficient functioning of your boiler. Please accept our renewed thanks for your purchase. Riello S.p.A.
  • Page 4: Precautions

    ENd USER GENERAL SAFETY INFORMATION The operation of any appliance that uses electrical power demands that a number of fundamental safety precautions be respected: Do not allow children or Never pull, disconnect, or twist the electrical cables infirm persons to operate coming from the boiler even if it is disconnected the boiler unsupervised.
  • Page 5: Control Panel

    ENd USER 3 CONTROL PANEL CONTROL OF BOILER, DIRECT CH ZONE AND DHW PRODUCTION Primary user interface / controls CONTROL PANEL IN CLOSEd POSITION CONTROL PANEL IN OPEN POSITION Electrical power indicator (green) Functioning mode selection key Lights to show that the boiler is receiving The selected mode is identified by a line under electrical power.
  • Page 6 ENd USER SECONDARY USER INFORMATION / DISPLAY Water pressure reading (not used) Large numeric display . Displays current value Chimney sweep or Service Required symbol Display mode symbols: DHW temperature or DHW mode active CH or room temperature setpoint, or CH mode active Outdoor temperature daytime mode Night-time mode...
  • Page 7 ENd USER MAIN SCREEN Functioning mode. Press the mode key to activate the various modes, as shown by the line under the corresponding symbol . dHW mode . Press the dHW (key (above the display) to activate and deactivate DHW mode. daytime mode Time of day Current boiler temperature...
  • Page 8 ENd USER pumps are switched on for 10 minutes at intervals of 6 Notes on functioning hours. If outside temperature is above 1.5°C the pumps The control panel on the ALUDOMUS SOLAR boiler also are switched off. controls the following functions.: Overtemperature dispersal function The DHW priority function If the temperature threshold thermostat trips (86°C) the...
  • Page 9 ENd USER INFORMATION LEVELS: Basic information level Press the key to enter the basic information le- vel. Press the again to scroll through the va- lues listed below . (*)The DHW key above the display. Functioning phases (table 1) Explanation Nr.
  • Page 10: Room Unit

    ENd USER 4 ROOM UNIT CONTROL OF SOLAR SYSTEM AND ANY ADDITIONAL SYSTEMS INSTALLED AS ACCESSORIES PRIMARY USER INTERFACE / CONTROLS DHW production on/off key. A line appears under the “v” symbol on the display when DHW production is enabled. Display ESCape key.
  • Page 11 ENd USER MAIN SCREEN A1 DHW production mode: ON or OFF . Press the DHW key (1) to switch DHW on or off (as shown by the line under the symbol). B1 Central heating modes: Press the central heating mode key (5) to activate the various modes as shown by the line under the corre sponding symbol.
  • Page 12 ENd USER Domestic hot water (DHW Press the DHW key (1) to enable domestic hot water pro- duction. A line appears under the DHW symbol. DHW is generated according to the DHW time program (parameters 560 to 566). Boiler temperature DHW production is switched off but the protection fun- ctions remain active.
  • Page 13 ENd USER o / l Presence If the rooms are not going to be used for some time, you can press the presence key (7) to reduce room tempera- ture and save energy. When you want to use the rooms again, simply press the presence key again to restore room temperature to the normal setpoint.
  • Page 14 ENd USER USER LEVELS: There are 4 different user levels : − End user − Commissioning − Heating engineer − OEM (Manufacturer). See the “Complete list of parameters” section for a list of the parameters displayed in each level. Proceed as follows to access the user level you require: Boiler temperature −...
  • Page 15 ENd USER − The display flashes the current hour. Turn the knob to go on or back to the correct value. Press "OK" to confirm. − The display flashes the current minutes. Turn the knob to go on or back to the correct value. Press "OK"...
  • Page 16: Start-Up

    ENd USER 5 START-UP Have ’s Technical Assistance Service start-up your boiler for the first time. Once this has been done, the boiler can be left to function automatically. Under certain circumstances, such as after long periods of disuse, the user may need to re-start it without involving the Technical Assistance Service.
  • Page 17 ENd USER − The display shows the system status and the temperature measured by the boiler tempera- ture sensor . Press the key: − With an outdoor temperature sensor connected you can now set the room temperature setpoint − With no outdoor temperature sensor connected you can now set the central heating circuit tem- perature setpoint.
  • Page 18 ENd USER SETTING CENTRAL HEATING PARAMETERS − Press the key: With an outdoor temperature sensor con- nected you can now set the room temperature setpoint. This setting shifts the heating curves (see the second figure on page 60) With no outdoor temperature sensor connected you can now set a fixed boiler temperature setpoint.
  • Page 19: List Of End User Level Parameters

    ENd USER 6 COMPLETE LIST OF PARAMETERS CONTROL PANEL: CONTROL OF BOILER, DIRECT CH ZONE AND DHW PRODUCTION LIST OF END USER LEVEL PARAMETERS N° Description Range Default setting Time of day 0…23.59 h/min Setpoints 5 (*) Line 5 will be hidden when using an additional room unit: Reduced room temperature setpoint 10…30 °C...
  • Page 20 ENd USER ROOM UNIT: CONTROL OF SOLAR SYSTEM AND ANY ADDITIONAL SYSTEMS INSTALLED AS ACCESSORIES Range Operating User Unit Function Default value line level Range Time of day and date Hours / minutes 00:00 23:59 hh:mm Day/month 01.01 31.12 dd .MM Year 2004 2099...
  • Page 21 ENd USER Range Operating User Unit Function Default value line level Range 3rd phase off 24:00 00:00 24:00 hh:mm Default values No ¦ Yes Time program 5 Preselection Mo - Su ¦ Mo - Fr ¦ Sa - Su ¦ Mo ¦ Tu ¦ We ¦ Mo - Su Th ¦...
  • Page 22 ENd USER Range Operating User Unit Function Default value line level Range release 907 (**) 24h/day ¦ Time programs HCs ¦ Time pro- 24 h/day gram 5 Heating circuit 2 Op line Operating 1010 Comfort cooling setpoint 20.0 °C 1012 line 1016 Op line Operating...
  • Page 23: Temporary Shutdown

    ENd USER 7 TEMPORARY SHUTdOWN If you are going to be away for a short period of time like a weekend or a short holiday, etc. proceed as follows: − Press and hold the key until the bar (1) appears under "stand-by" mode. Provided power to the boiler remains switched on, as shown by the green LED, and the fuel supply remains open, the boiler remains protected by the frost protec-...
  • Page 24: Error Codes/Maintenance

    ENd USER 8.1 Error codes CONTROL PANEL: CONTROL OF BOILER, DIRECT CH ZONE AND DHW PRODUCTION TEMPORARY ERROR DISPLAY − If a temporary error occurs, the display alterna- tes between displaying the time display and the error code − Press the key to display the error code on the main display −...
  • Page 25 ENd USER PERMANENT ERROR DISPLAY − If a permanent error occurs, the error code flashes on the main display. The controller per- forms a safety shutdown. Example: E154. − Press the to display the error code on the main display. −...
  • Page 26 ENd USER ERROR TABLE Number Type Description No input code Outdoor sensor error Boiler sensor 1 error Flue gas sensor error CH flow sensor 2 error CH return sensor 1 error DHW sensor 1 error dHW sensor 2 error Room unit 1 error Room unit 1 or timer connection error Solar collector sensor error (if solar clip-in option is installed) Air pressure sensor error (not used)
  • Page 27 ENd USER ROOM UNIT: CONTROL OF SOLAR SYSTEM AND ANY ADDITIONAL SYSTEMS INSTALLED AS ACCESSORIES When an error occurs, press the key (6) to display the error message. The message on the display descri- bes the cause of the error. If an error occurs, an alarm may also activate a suitably configured Qx...
  • Page 28 ENd USER Error code Description Radio communications Expansion module 1 Expansion module 2 2 master clocks Missing clock reserve Boiler temperature monitoring Lockout for safety thermostat tripped Error 30: Flow sensor 1 High water pressure (not used) Low water pressure (not used) Circuit flow temperature 1 Circuit flow temperature 2 Anti-legionnaires temperature...
  • Page 29: Cleaning

    ENd USER 9 CLEANING Use a cloth damped in soapy water to clean the boiler’s external panelling. To remove stubborn marks, use a cloth damped in a 50% mix of water and denatured alcohol or a suitable cleaning product. Wipe the boiler dry after cleaning it.
  • Page 30: Useful Information

    ENd USER 11 USEFUL INFORMATION Seller: Installer: Mr.: ................ Mr.: ................ Address: ..............Address: ..............Tel.: ................ Tel.: ................ Technical Assistance Service: Mr.: ................ Address: ..............Tel.: ................ Date Work done Fuel oil supplier: Mr.: ................ Address: ..............Tel.: ................ Quantity Quantity Quantity...