Riello ALUDOMUS SOLAR KV/200 20 ISC SOLAR Installation And Maintenance Manual page 72

Hide thumbs Also See for ALUDOMUS SOLAR KV/200 20 ISC SOLAR:
Table of Contents

Advertisement

THECNICAL ASSISTANCE SERVICE
Error
Diagnostic
code via
info
QAA
129
87
129
89
129
90
130
508
130
509
132
77
132
92
132
93
132
94
132
285
133
101
133
102
140
521
148
517
Description of
Type of fault
error
Comburent air
Fan speed below mini-
system error
Comburent air
Fan speed below mini-
system error
Comburent air
Fan speed has fallen be-
system error
low pre-purge speed
TaAbschal parameter
Flue gas tempe-
(flue gas temperatu-
rature threshold
re threshold for boiler
exceeded
shutdown) exceeded
TaBegrenz parameter
Flue gas tempe-
(flue gas temperature th-
rature threshold
reshold for reducing heat
exceeded
output) exceeded
The input has been
configured as a switch
Water pressure
that prevents start-up
switch tripped
(FaEinstellFlags2) and the
switch is open
The input has been
configured as a switch
Water pressure
that prevents start-up
switch tripped
(FaEinstellFlags2) and the
switch is open
The pressure switch has
been configured as a
Water pressure
switch that prevents
switch tripped
start-up (FaEinstellFlags2)
and the switch is open
during safety time
The pressure switch has
been configured as a
switch that prevents
Water pressure
start-up (FaEinstellFlags2)
switch tripped
and the switch is open
during safety time. Start-
up prevented for two
Shutdown at wrong
Water pressure
time. The error masking
switch tripped
time has been interrup-
The flame does not
appear at the end of the
No flame
safety time--> Repeti-
The flame does not
No flame
appear at the end of the
safety time
Illegal LPB ad-
Illegal segment number
dress
or LPB device number
Interface/base
LPB incompatibility
unit LPB incom-
between interface unit
patibility
and base unit
System action
Burner lockout
(permanent).
mum
Lockout reset re-
quired
Safety shutdown
mum
Burner lockout
(permanent).
Lockout reset re-
quired
Safety shutdown
Message
Safety shutdown
Safety shutdown
Safety shutdown
Safety shutdown
hours
Safety shutdown
ted
Safety shutdown
tion
Burner lockout
(permanent).
Lockout reset re-
quired
Message
Message
72
Procedure
Check the air pressu-
re switch; check the
air intake pipe; check
the fan
Check the air pressu-
re switch; check the
air intake pipe; check
the fan
Check the air pressu-
re switch; check the
air intake pipe; check
the fan
Check the flue gas
vent; check the
temperature sensor;
check the burner;
check setting of pa-
rameter 592
Check the flue gas
vent; check the
temperature sensor;
check the burner;
check setting of pa-
rameter 591
Check the system
pressure
Check the system
pressure
Check the system
pressure
Check the system
pressure
Check the system
pressure
Check the connec-
tions to the burner
Check the connec-
tions to the burner
Contact Technical
Assistance Service
Contact Technical
Assistance Service