Installing An Additional Microprocessor And Heat Sink - Lenovo System x3650 M4 Installation And Service Manual

Machine type: 7915
Hide thumbs Also See for System x3650 M4:
Table of Contents

Advertisement

Step 1.
Read the safety information that begins on "Safety" on page v and "Installation guidelines"
on page 34.
Step 2.
Turn off the server and peripheral devices and disconnect the power cords.
Step 3.
Remove the cover (see "Removing the cover" on page 37).
Step 4.
Remove PCI riser-card assembly (see "Removing a PCI riser-card assembly" on page 37).
Step 5.
Align the flash device with the connector on the system board and push it into the USB connector
until it is firmly seated.
Step 6.
Pull up the blue locking collar to lock the flash device into the USB connector.
USB embedded
hypervisor
flash device
Figure 119. USB hypervisor flash device installation
If you have other devices to install or remove, do so now. Otherwise, go to "Completing the installation" on
page 136.
Note: You must configure the server to boot from the hypervisor USB drive. See Chapter 3 "Configuration
information and instructions" on page 141 for information about enabling the embedded hypervisor.

Installing an additional microprocessor and heat sink

Use this information to install an additional microprocessor and heat sink.
The following notes describe the type of microprocessor that the server supports and other information that
you must consider when you install a microprocessor and heat sink:
• Microprocessors are to be installed only by trained technicians.
Lockbar
.
Chapter 2
Installing optional devices
127