Lenovo System x3650 M4 Installation And Service Manual page 302

Machine type: 7915
Hide thumbs Also See for System x3650 M4:
Table of Contents

Advertisement

Flash power
module cable
Flash power
module
Figure 204. Connecting the flash power module cable
Note: Make sure the battery/flash power module is seated properly (see "Installing a ServeRAID
SAS controller battery on the remote battery tray" on page 65).
Step 7.
Reconnect the power cord and any cables that you removed.
Step 8.
Reinstall the cover (see "Replacing the cover" on page 240).
Step 9.
Slide the server into the rack.
Step 10. Turn on the peripheral devices and the server.
Removing a remotely installed RAID adapter battery/flash power module
Use this information to remove a remotely installed RAID adapter battery/flash power module.
If a RAID adapter battery / flash power module is installed near the fan cage and you need to replace it,
complete the following steps:
Step 1.
Read the safety information that begins on "Safety" on page v and "Installation guidelines"
on page 34.
Step 2.
Turn off the server and peripheral devices and disconnect all power cords.
Step 3.
Remove the cover (see "Removing the cover" on page 240).
Step 4.
Remove any cable covering or obstructing the battery/flash power module holder before opening
the battery/flash power module holder.
Step 5.
Pull the release tab toward the fan cage and unlock the retention clip.
290
Lenovo System x3650 M4 Installation and Service Guide
ServeRAID memory module