Hypervisor Problems - Lenovo System x3650 M4 Installation And Service Manual

Machine type: 7915
Hide thumbs Also See for System x3650 M4:
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
• Go to the support website at http://www.lenovo.com/support to check for technical information, hints, tips,
and new device drivers or to submit a request for information.
Symptom
Multiple hard disk drives fail.
Multiple hard disk drives are
offline.
A replacement hard disk drive
does not rebuild.
A green hard disk drive activity
LED does not accurately
represent the actual state of
the associated drive.
An yellow hard disk drive
status LED does not accurately
represent the actual state of
the associated drive.

Hypervisor problems

Use the troubleshooting tables to find solutions to problems that have identifiable symptoms.
Action
7. Reseat the backplane signal cable and repeat steps 2 through 4.
8. Suspect the backplane signal cable or the backplane:
• If the server has eight hot-swap bays:
a. Replace the affected backplane signal cable.
b. Replace the affected backplane.
9. See "Problem determination tips" on page 209.
Make sure that the hard disk drive, SAS/SATA adapter, and server device drivers
and firmware are at the latest level.
Important: Some cluster solutions require specific code levels or coordinated code
updates. If the device is part of a cluster solution, verify that the latest level of code
is supported for the cluster solution before you update the code.
1. Review the storage subsystem logs for indications of problems within the
storage subsystem, such as backplane or cable problems.
2. See "Problem determination tips" on page 209.
1. Make sure that the hard disk drive is recognized by the adapter (the green hard
disk drive activity LED is flashing).
2. Review the SAS/SATA adapter documentation to determine the correct
configuration parameters and settings.
If the green hard disk drive activity LED does not flash when the drive is in use, run
the DSA Preboot diagnostic programs to collect error logs (see "Running the DSA
Preboot diagnostic programs" on page 187).
• If there is a hard disk drive error log, replace the affected hard disk drive.
• If there is no disk drive error log error log, replace the affected backplane.
1. If the yellow hard disk drive LED and the RAID adapter software do not indicate
the same status for the drive, complete the following steps:
a. Turn off the server.
b. Reseat the SAS/SATA adapter.
c. Reseat the backplane signal cable and backplane power cable.
d. Reseat the hard disk drive.
e. Turn on the server and observe the activity of the hard disk drive LEDs.
2. See "Problem determination tips" on page 209.
.