Lenovo System x3650 M4 Installation And Service Manual page 269

Machine type: 7915
Hide thumbs Also See for System x3650 M4:
Table of Contents

Advertisement

Figure 172. DVD drive removal
Step 5.
Slide the drive retention clip from the side of the drive. Save the clip to use when you install the
replacement drive or replace the DVD drive filler panel.
Drive retention clip
Alignment pins
Figure 173. DVD drive retention clip removal
Step 6.
Attach the drive retention clip to the side of the DVD drive filler panel that you removed.
Step 7.
Slide the DVD drive filler panel into the DVD drive bay until the DVD drive filler panel clicks into place.
Step 8.
If you are instructed to return the DVD drive, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.
Replacing a DVD drive
Use this information to install a DVD drive.
The following notes describe the type of drives that the server supports and other information that you must
consider when you install a drive. For a list of supported drives, see http://www.lenovo.com/ serverproven/.
• Locate the documentation that comes with the drive and follow those instructions in addition to the
instructions in this chapter.
• Make sure that you have all the cables and other equipment that are specified in the documentation that
comes with the drive.
• The server supports one ultra-slim SATA optical drive.
To install an optional DVD drive, complete the following steps:
Release tab
.
Chapter 6
Removing and replacing components
257