SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0522
User Response
1. Make sure that there are no obstructions, such as bundled cables, to the airflow from the
power-supply fan.
2. Use the IBM Power Configurator utility to ensure current system power consumption
is under limitation. For more information and to download the utility, go to
http://www-03.ibm.com/systems/bladecenter/resources/powerconfig.html.
3. Replace power supply n. (n = power supply number)
• 8007020c-2502ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (nvDIMM 02 Status)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 8007020c2502ffff or 0x8007020c2502ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
None
• 8007020c-2505ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (nvDIMM 05 Status)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 8007020c2505ffff or 0x8007020c2505ffff
Severity
460
Lenovo System x3650 M4 Installation and Service Guide