Chapter 14
Environmental Monitoring and Power Management
If a 9000W power supply is installed in the left bay, the show logging onboard subslot 0 detail
command displays logging information for that power supply.
If a 9000W power supply is installed in the right bay, enter the show logging onboard subslot 1 detail
command, as follows:
Switch# show logging onboard subslot 0 detail
PID: WS-C4506-E
--------------------------------------------------------------------------------
ERROR MESSAGE SUMMARY INFORMATION
--------------------------------------------------------------------------------
Facility-Sev-Name
MM/DD/YYYY HH:MM:SS
--------------------------------------------------------------------------------
No historical data to display
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
ERROR MESSAGE CONTINUOUS INFORMATION
--------------------------------------------------------------------------------
MM/DD/YYYY HH:MM:SS Facility-Sev-Name
--------------------------------------------------------------------------------
08/20/2012 08:06:23
Input 1
08/20/2012 08:06:23
t 1, Input 1
09/09/2012 21:12:28
t 1, Input 3
09/09/2012 21:22:30
t 1, Input 3
09/09/2012 21:32:32
t 1, Input 3
09/10/2012 00:05:49
Input 1
09/10/2012 00:05:49
t 1, Input 1
--------------------------------------------------------------------------------

Emergency Actions

Catalyst 4500 chassis can power down a single card, providing a detailed response to over-temperature
conditions on line cards. However, the Catalyst 4500 chassis cannot safely operate when the temperature
of the supervisor itself exceeds the critical threshold. The supervisor engine turns off the chassis' power
supplies to protect itself from overheating. When this happens, you can recover the switch only by
cycling the power on and off switches on the power supplies or by cycling the AC or DC inputs to the
power supplies.
Critical and shutdown temperature emergencies trigger the same action. Table 14-2 lists temperature
emergencies but does not distinguish between critical and shutdown emergencies.
Table 14-2
Case 1. Complete fan failure emergency.
Case 2. Temperature emergency on a line
card.
Case 3. Temperature emergency on the
standby supervisor engine.
, VID: 4
| Count | Persistence Flag
%CAT4K-2-POWER_SAG : 5 Power Sag event(s) detected: Slot 1,
%CAT4K-2-POWER_SURGE : 5 Power Surge event(s) detected: Slo
%CAT4K-2-POWER_SURGE : 5 Power Surge event(s) detected: Slo
%CAT4K-2-POWER_SURGE : 5 Power Surge event(s) detected: Slo
%CAT4K-2-POWER_SURGE : 5 Power Surge event(s) detected: Slo
%CAT4K-2-POWER_SAG : 1 Power Sag event(s) detected: Slot 1,
%CAT4K-2-POWER_SURGE : 1 Power Surge event(s) detected: Slo
Emergency and Action
Catalyst 4500 Series Switch, Cisco IOS Software Configuration Guide - Cisco IOS XE 3.9.xE and IOS 15.2(5)Ex
, SN: FOX1347GR85
Power down the chassis.
Power down the line card.
Power down the standby supervisor engine.
About Environmental Monitoring