Displaying Etherchannel Links To Vss - Cisco Catalyst 4500 Series Software Configuration Manual

Cisco ios xe release 3.9.xe and cisco ios release 15.2(5)ex
Hide thumbs Also See for Catalyst 4500 Series:
Table of Contents

Advertisement

Chapter 27
Configuring EtherChannel and Link State Tracking

Displaying EtherChannel Links to VSS

To display the dual-active detection capability of a configured PAgP port channel, enter the
show pagp port_channel_number dual-active command.
The command provides the following information:
Note
You can also see the name of the neighboring switch (Partner Name) and the ports to which this
EtherChannel is connected (Partner Port).
If a Catalyst 4500 switch is connected to a Catalyst 6500 series VSS with the same version of enhanced
PAgP dual-active detection, the switch can detect a dual-active scenario:
Switch# show pagp 1 dual-active
PAgP dual-active detection enabled: Yes
PAgP dual-active version: 1.1
Channel group 1
Port
Gi6/5
Gi6/6
If a Catalyst 4500 switch is not connected to a Catalyst 6500 series VSS, the switch cannot detect a
dual-active scenario:
Switch# show pagp 1 dual-active
PAgP dual-active detection enabled: Yes
PAgP dual-active version: 1.1
Channel group 1
Port
Gi6/5
Gi6/6
Understanding Link-State Tracking
Link-state tracking, also known as trunk failover, is a feature that binds the link state of multiple
interfaces. For example, link-state tracking provides redundancy in the network when used with server
NIC adapter teaming. When server network adapters are configured in a primary or secondary
relationship known as teaming, if the link is lost on the primary interface, connectivity is transparently
changed to the secondary interface.
A switch uses enhanced PAgP for dual-active detection.
You should always see Yes after PAgP dual-active diction enabled on a Catalyst 4500 switch.
The configured PAgP EtherChannel is connected to a Catalyst 6500 switch VSS.
You see N/A below Partner Version if this EtherChannel is not connected to a VSS. Otherwise, you
see the version of enhanced PAgP dual-active detection implemented in the VSS.
This switch is capable of detecting dual-active scenarios in the connected VSS.
You see Yes below Dual-Active Detect Capable if and only if the configured EtherChannel is
connected to a Catalyst 6500 series VSS that uses the same version of enhanced PAgP dual-active
detection.
Dual-Active
Partner
Detect Capable
Name
Yes
VSS
Yes
VSS
Dual-Active
Partner
Detect Capable
Name
No
Switch
No
Switch
Catalyst 4500 Series Switch, Cisco IOS Software Configuration Guide - Cisco IOS XE 3.9.xE and IOS 15.2(5)Ex
Partner
Partner
Port
Version
Gi1/8/1
1.1
Gi2/8/1
1.1
Partner
Partner
Port
Version
Fa6/5
N/A
Fa6/6
N/A
Understanding Link-State Tracking
27-23

Advertisement

Table of Contents
loading