Conditions Window Actions; Figure 11-3 Viewing Conditions In The Conditions Window; Table 11-5 Conditions Display - Cisco ONS 15600 Reference Manual

Hide thumbs Also See for ONS 15600:
Table of Contents

Advertisement

11.2.4 Conditions Window Actions

11.2.4 Conditions Window Actions
Table 11-5
Table 11-5
Button
Retrieve
Filter
The current set of all existing conditions maintained by the alarm manager appears when you click the
Retrieve button. The set of conditions retrieved is relative to the view. For example, if you click the
button in the node view, node-specific conditions appear
in the network view, all conditions for the network (including ONS 15600 nodes and other connected
nodes such as ONS 15454s) appear, and the card view shows only card-specific conditions.
Figure 11-3
Cisco ONS 15600 Reference Manual, R6.0
11-6
shows the actions you can perform in the Conditions window.
Conditions Display
Action
Retrieves the current set of all existing fault conditions, as maintained by
the alarm manager, from the ONS 15600.
Allows you to change the Conditions window display to only show the
conditions that meet a certain severity level or occur in a specified time. For
example, you can set the filter so that only Critical conditions display on
the window.
There is a Filter icon button in the lower-right corner of the window that
allows you to enable or disable the filter feature.
Viewing Conditions in the Conditions Window
Chapter 11
Alarm Monitoring and Management
(Figure
11-3). If you click the Retrieve button

Advertisement

Table of Contents
loading

Table of Contents