Managing Software Licenses Using Permanent Right-To-Use Features

If summer time in your area does not follow a recurring pattern (configure the exact date and time of the
next summer time events), perform this task:
Command
Step 1
configure terminal
Step 2
clock summer-time zone date
date year hh:mm month date year
[
]]
hh:mm
offset
or
clock summer-time zone date
month year hh:mm date month year
[
]]
hh:mm
offset
Step 3
end
Step 4
show running-config
Step 5
copy running-config startup-config
The first part of the clock summer-time global configuration command specifies when summer time
begins, and the second part specifies when it ends. All times are relative to the local time zone. The start
time is relative to standard time. The end time is relative to summer time. If the starting month is after
the ending month, the system assumes that you are in the southern hemisphere.
To disable summer time, use the no clock summer-time global configuration command.
This example shows how to set summer time to start on October 12, 2000, at 02:00, and end on April 26,
2001, at 02:00:
Switch# configure terminal
Switch(config)# clock summer-time pdt date 12 October 2000 2:00 26 April 2001 2:00
Switch#
Managing Software Licenses Using Permanent Right-To-Use
Features
If you want to upgrade or downgrade from one license level to another, we recommend that you use the
permanent right-to-use (PRTU) license instead of the node-locked license.
Catalyst 4500 Series Switch, Cisco IOS Software Configuration Guide - Cisco IOS XE 3.9.xE and IOS 15.2(5)Ex
4-14
Purpose
Enters global configuration mode.
[
Configures summer time to start on the first date and end on the second
month
date.
To disable summer time, use the no clock summer-time global
[
date
configuration command.
Summer time is disabled by default.
Returns to privileged EXEC mode.
Verifies your entries.
(Optional) Saves your entries in the configuration file.
About a PRTU License, page 4-15
Guidelines for the RTU License Model, page 4-16
Applying a PRTU License, page 4-16
For zone, specify the name of the time zone (for example, PDT) to be
displayed when summer time is in effect.
(Optional) For week, specify the week of the month (1 to 5 or last).
(Optional) For day, specify the day of the week (Sunday, Monday...).
(Optional) For month, specify the month (January, February...).
(Optional) For hh:mm, specify the time (24-hour format) in hours and
minutes.
(Optional) For offset, specify the number of minutes to add during
summer time. The default is 60.
Chapter 4