Booting a Module After if it has been Stopped

To bring up a module that has been stopped using the hw-module module number stop command or by pressing the OIR
button, you either enter the hw-module module number start command or physically remove and reinsert.
The following example shows what happens if a module has been stopped and you enter this command:
Switch# hw-module module 2 start
Switch#
*Feb
5 16:36:27.352: %C4K_IOSMODPORTMAN-6-MODULEINSERTED: Module 2 is inserted
*Feb
5 16:37:15.902: %C4K_IOSMODPORTMAN-6-MODULEONLINE: Module 2 (WS-X4908X-10G-TIM S/N: JAE15340C0J Hw:
0.1) is online
Switch# show module
Chassis Type : WS-C4500X-32
Power consumed by backplane : 0 Watts
Mod Ports Card Type
---+-----+--------------------------------------+------------------+-----------
1
32
4500X-32 10GE (SFP+)
2
8
10GE SFP+
M MAC addresses
--+--------------------------------+---+------------+----------------+---------
1 0022.bde2.1061 to 0022.bde2.1080 0.2 15.0(1r)SG(0 0.DEV-0
2 0022.bde2.1579 to 0022.bde2.1580 0.1
Switch#
The following example shows what happens if a module has not been stopped and you enter this command:
Switch# hw-module module 2 start
% Module 2 not stopped
Common Scenarios
Table 9-9
lists the common scenarios associated with an OIR on a WS-4500X-32.
Table 9-9
If you do this or want to do this...
Insert a new module for the first time.
Pull out an uplink module that was not previously
stopped or shut down.
Press the OIR button accidentally.
Change your mind after entering the module stop
command or pressing the OIR button.
Chapter 9
Configuring Interfaces
Model
WS-C4900X-32P-10G
WS-X4908X-10G-TIM
Hw
Fw
Common Scenarios for OIR on a WS-4500X-32
Catalyst 4500 Series Switch, Cisco IOS Software Configuration Guide - Cisco IOS XE 3.9.xE and IOS
Online Insertion and Removal on a WS-4500X-32
Serial No.
JAE153505E9
JAE15340C0J
Sw
Status
Ok
Ok
This happens or you need to do this....
The behavior of new module matches that of
current linecard.
The system reboots to ROMMON.
Press for less than 5 sec and nothing happens.
Press for more than 5 sec and OIR is initiated. The
linecard moves to the reset state and the OIR LED
turns GREEN.
Enter the module start command or perform a
physical OIR. Both actions trigger uplink module
restart. If the module is not faulty, it is restored to
online state.