Electrical Safety Guidelines And Warnings; General Electrical Safety Guidelines And Warnings - Juniper EX9214 Hardware Manual

Ex series
Hide thumbs Also See for EX9214:
Table of Contents

Advertisement

CHAPTER 35

Electrical Safety Guidelines and Warnings

General Electrical Safety Guidelines and Warnings

Copyright © 2017, Juniper Networks, Inc.
General Electrical Safety Guidelines and Warnings on page 327
Action to Take After an Electrical Accident on page 328
Prevention of Electrostatic Discharge Damage on page 329
AC Power Electrical Safety Guidelines on page 330
AC Power Disconnection Warning on page 331
DC Power Electrical Safety Guidelines for Switches on page 332
DC Power Disconnection Warning on page 335
DC Power Grounding Requirements and Warning on page 336
DC Power Wiring Sequence Warning on page 337
DC Power Wiring Terminations Warning on page 339
Multiple Power Supplies Disconnection Warning on page 340
TN Power Warning on page 340
WARNING:
Certain ports on the device are designed for use as intrabuilding
(within-the-building) interfaces only (Type 2 or Type 4 ports as described in
GR-1089-CORE) and require isolation from the exposed outside plant (OSP)
cabling. To comply with NEBS requirements and protect against lightning
surges and commercial power disturbances, the intrabuilding ports must not
be metallically connected to interfaces that connect to the OSP or its wiring.
The intrabuilding ports on the device are suitable for connection to
intrabuilding or unexposed wiring or cabling only. The addition of primary
protectors is not sufficient protection for connecting these interfaces
metallically to OSP wiring.
CAUTION:
Before removing or installing components of a device, attach an
electrostatic discharge (ESD) grounding strap to an ESD point and place the
other end of the strap around your bare wrist. Failure to use an ESD grounding
strap could result in damage to the device.
327