EX9214 Switch Hardware Guide
210
Rotate both the ejector handles simultaneously clockwise until the SF module is fully
8.
seated. Place the ejector handles in the proper position, horizontally and toward the
center of the board.
Verify that the SF module is installed correctly and functioning normally by checking
9.
the LEDs on the faceplate of the SF module.
The
LED glows steady green a few minutes after the SF module is
OK/FAIL
successfully installed.
If the
OK/FAIL
LED is red, remove and install the SF module again. If the
LED is still red or is off, the SF module is not functioning properly. Contact your
customer support representative.
Check the status of the SF using the
10.
user@switch> show chassis environment cb
CB 0 status:
State
Temperature
Power 1
1.0 V
1.2 V
1.5 V
1.8 V
2.5 V
3.3 V
5.0 V
5.0 V RE
12.0 V
12.0 V RE
Power 2
4.6 V bias MidPlane
11.3 V bias PEM
11.3 V bias FPD
11.3 V bias POE 0
11.3 V bias POE 1
Bus Revision
FPGA Revision
PMBus
Expected
device
voltage
XF ASIC A
XF ASIC B
CB 1 status:
State
Temperature
Power 1
1.0 V
1.2 V
1.5 V
1.8 V
2.5 V
3.3 V
5.0 V
5.0 V RE
12.0 V
12.0 V RE
Power 2
4.6 V bias MidPlane
show chassis environment cb
Online Master
29 degrees C / 84 degrees F
1002 mV
1218 mV
1472 mV
1830 mV
2526 mV
3338 mV
5059 mV
4969 mV
12239 mV
12123 mV
4840 mV
11176 mV
11292 mV
11272 mV
11311 mV
64
13
Measured
Measured
voltage
current
1000 mV
997 mV
13625 mA
1000 mV
1000 mV
12484 mA
Online Standby
29 degrees C / 84 degrees F
1002 mV
1214 mV
1472 mV
1807 mV
2520 mV
3319 mV
5059 mV
4969 mV
12258 mV
12239 mV
4840 mV
OK/FAIL
command:
Calculated
power
13584 mW
12484 mW