To install an RE module in an EX9200 switch:
Attach the ESD grounding strap to your bare wrist and connect the strap to one of the
1.
ESD points on the chassis.
Taking care not to touch the leads, pins, or solder connections, pull the RE module
2.
out from the bag.
Ensure that the ejector handles are not in the locked position. If necessary, flip the
3.
ejector handles outward.
Place one hand underneath the RE module to support it.
4.
Carefully align the sides of the RE module with the guides inside the RE module slot
5.
on the SF.
Slide the RE module into the SF module until you feel resistance, and then press in
6.
the faceplate of the RE module until it engages the connectors.
Press both of the ejector handles inward to seat the RE module.
7.
Tighten the screws, one on each side of the RE module, using a screwdriver.
8.
Connect the management device cables to the RE module.
9.
The RE module might require several minutes to boot.
After the RE module boots, verify that it is installed correctly by checking the
RE1
LEDs on the craft interface. If the switch is operational and the Routing Engine is
functioning properly, the
steadily instead, remove and install the RE module again. If the
red steadily, the RE module is not functioning properly. Contact your customer support
representative.
You can use the
show chassis routing-engine
Engines.
Figure 67 on page 201
shows installing an RE module in an EX9204 switch. The procedure
is the same for all EX9200 switches.
LED glows steady green. If the
ONLINE
command to check the status of Routing
RE0
LED glows red
FAIL
LED still glows
FAIL
Copyright © 2017, Juniper Networks, Inc.
and