Juniper EX9214 Hardware Manual page 112

Ex series
Hide thumbs Also See for EX9214:
Table of Contents

Advertisement

EX9214 Switch Hardware Guide
Table 38: EX Series Switch Environmental Tolerances (continued)
Environment Tolerance
Switch or
device
Altitude
EX9214
No performance
degradation up to
10,000 feet
(3048 meters)
XRE200
No performance
degradation up to
10,000 feet
(3048 meters)
Related
Documentation
88
Relative Humidity
Normal operation ensured in
the relative humidity range
5% through 90%
(noncondensing)
Normal operation ensured in
the relative humidity range
10% through 85%
(noncondensing)
NOTE:
Install EX Series switches only in restricted areas, such as dedicated
equipment rooms and equipment closets, in accordance with Articles 110–16,
110–17, and 110–18 of the National Electrical Code, ANSI/NFPA 70.
Clearance Requirements for Airflow and Hardware Maintenance for EX2200 Switches
Clearance Requirements for Airflow and Hardware Maintenance for EX2300 Switches
Clearance Requirements for Airflow and Hardware Maintenance for EX3200 Switches
Clearance Requirements for Airflow and Hardware Maintenance for EX3300 Switches
Clearance Requirements for Airflow and Hardware Maintenance for EX3400 Switches
Clearance Requirements for Airflow and Hardware Maintenance for EX4200 Switches
Clearance Requirements for Airflow and Hardware Maintenance for EX4300 Switches
Clearance Requirements for Airflow and Hardware Maintenance for an EX4600 Switch
Clearance Requirements for Airflow and Hardware Maintenance for an EX Series
Redundant Power System
Clearance Requirements for Airflow and Hardware Maintenance for EX4500 Switches
Clearance Requirements for Airflow and Hardware Maintenance for EX4550 Switches
Clearance Requirements for Airflow and Hardware Maintenance for an EX6210 Switch
Clearance Requirements for Airflow and Hardware Maintenance for an EX8208 Switch
Clearance Requirements for Airflow and Hardware Maintenance for an EX8216 Switch
Clearance Requirements for Airflow and Hardware Maintenance for an EX9204 Switch
Clearance Requirements for Airflow and Hardware Maintenance for an EX9208 Switch
Temperature
Normal operation is ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
Nonoperating storage
temperature in shipping
container: –40° F (–40° C)
through 158° F (70° C)
Normal operation ensured in the
temperature range 41° F (5° C)
through 104° F (40° C)
Copyright © 2017, Juniper Networks, Inc.
Seismic
Complies with Zone 4
earthquake
requirements as per
GR-63.
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.

Advertisement

Table of Contents
loading

Table of Contents