Page 2
END USER LICENSE AGREEMENT The Juniper Networks product that is the subject of this technical documentation consists of (or is intended for use with) Juniper Networks software. Use of such software is subject to the terms and conditions of the End User License Agreement (“EULA”) posted at http://www.juniper.net/support/eula.html.
Page 4
Port Mirroring Feature Guide for EX9200 Switches Part 2 Configuring Port Mirroring Chapter 5 Port Mirroring Instances ..........21 Configuring the Global Instance of Layer 2 Port Mirroring .
Page 6
Port Mirroring Feature Guide for EX9200 Switches Chapter 16 Operational Commands: Next-Hop Groups for Layer 2 Port Mirroring . . . 427 show forwarding-options port-mirroring ....... 428 show forwarding-options next-hop-group .
® To obtain the most current version of all Juniper Networks technical documentation, see the product documentation page on the Juniper Networks website at http://www.juniper.net/techpubs/ If the information in the latest release notes differs from the information in the documentation, follow the product Release Notes.
Port Mirroring Feature Guide for EX9200 Switches If the example configuration does not start at the top level of the hierarchy, the example is a snippet. In this case, use the command. These procedures are load merge relative described in the following sections.
Page 14
Port Mirroring Feature Guide for EX9200 Switches Table 2: Text and Syntax Conventions (continued) Convention Description Examples Fixed-width text like this Represents output that appears on the user@host> show chassis alarms terminal screen. No alarms currently active Italic text like this...
We encourage you to provide feedback, comments, and suggestions so that we can improve the documentation. You can provide feedback by using either of the following methods: Online feedback rating system—On any page of the Juniper Networks TechLibrary site , simply click the stars to rate the content, http://www.juniper.net/techpubs/index.html and use the pop-up form to provide us with information about your experience.
Download the latest versions of software and review release notes: http://www.juniper.net/customers/csc/software/ Search technical bulletins for relevant hardware and software notifications: http://kb.juniper.net/InfoCenter/ Join and participate in the Juniper Networks Community Forum: http://www.juniper.net/company/communities/ Open a case online in the CSC Case Management tool: http://www.juniper.net/cm/...
This is known as port mirroring. In Junos OS Release 9.3 and later, Juniper Networks MX Series 3D Universal Edge Routers in a Layer 2 environment support port mirroring for Layer 2 bridging traffic and virtual private LAN service (VPLS) traffic.
Port Mirroring Feature Guide for EX9200 Switches Related Understanding Layer 2 Port Mirroring Properties on page 4 Documentation Restrictions on Layer 2 Port Mirroring Application of Layer 2 Port Mirroring Types Application of Layer 2 Port Mirroring Types Understanding Layer 2 Port Mirroring Properties...
Port Mirroring Feature Guide for EX9200 Switches Table 3: Application of Layer 2 Port Mirroring Types Type of Layer2PortMirroring Point of Scope of Configuration Definition Application Mirroring Description Details Global Instance of All ports in the MX VPLS packets If configured, the global port-mirroring...
Port Mirroring Feature Guide for EX9200 Switches Layer 2 Port Mirroring Named Instances Overview On an MX Series router and on an EX Series switch, you can define a set of port-mirroring properties that you can explicitly bind to physical ports on the router or switch. This set of port mirroring properties is known as a named instance of Layer 2 port mirroring.
Port Mirroring Feature Guide for EX9200 Switches Table 4: Application of Layer 2 Port Mirroring Firewall Filters on PE Devices Point of Application Scope of Mirroring Notes Configuration Details Ingress Customer-Facing Packets originating within a You can also configure See Applying Layer 2 Port Logical Interface service provider customer’s...
Page 34
Port Mirroring Feature Guide for EX9200 Switches first binding in the stanza (or the only binding) is used at the logical interface. This is done mainly for backward compatibility. Layer 2 port-mirroring firewall filters do not support the use of next-hop subgroups for load-balancing mirrored traffic.
Page 38
Port Mirroring Feature Guide for EX9200 Switches Specify global-level packet-selection properties. Specify the number of packets to select: [edit forwarding-options port-mirroring input] user@host# set rate number The valid range is through 65535 Specify the number of packets to mirror from each selection:...
Port Mirroring Feature Guide for EX9200 Switches Related Understanding Layer 2 Port Mirroring on page 3 Documentation Layer 2 Port Mirroring Global Instance on page 9 Examples: Layer 2 Port Mirroring at Multiple Levels of the Chassis on page 34...
Page 42
Port Mirroring Feature Guide for EX9200 Switches [edit forwarding-options port-mirroring instance pm-instance-name family family] user@host# edit output Specify mirror destination properties. Specify the physical interface on which to send the mirrored packets: [edit forwarding-options port-mirroring instance pm-instance-name family family output]...
Port Mirroring Feature Guide for EX9200 Switches Related Understanding Layer 2 Port Mirroring on page 3 Documentation Restrictions on Layer 2 Port Mirroring Application of Layer 2 Port Mirroring Types Understanding Layer 2 Port Mirroring of PE Router Logical Interfaces on page 41...
Port Mirroring Feature Guide for EX9200 Switches Binding Layer 2 Port Mirroring to Ports Grouped at the PIC Level On an MX Series router and on an EX Series switch, you can bind a named instance of Layer 2 port mirroring to the ports associated with a specific Packet Forwarding Engine (on a DPC) or to the ports associated with a specific PIC (installed in an FPC).
Port Mirroring Feature Guide for EX9200 Switches To disable the definition of a particular named instance of Layer 2 port mirroring, include statement at the disable [edit forwarding-options port-mirroring instance hierarchy level: instance-name] [edit] forwarding-options { port-mirroring { ...optional-configuration-of-the-global-instance-of-layer-2-port-mirroring... instance { port-mirroring-instance-name { disable;...
Port Mirroring Feature Guide for EX9200 Switches hierarchy level. The Layer 2 port mirroring named instances [edit interfaces] must be configured at the hierarchy [edit forwarding-options port-mirroring instance] level. Related Understanding Layer 2 Port Mirroring on page 3 Documentation Layer 2 Port Mirroring Global Instance on page 9...
Page 54
Port Mirroring Feature Guide for EX9200 Switches Configure two Layer 2 port-mirroring firewall filters, both for VLAN traffic and with one of the filters explicitly referencing one of the named instances of Layer 2 port mirroring: Configure the filter pm_filter_1...
Page 56
Port Mirroring Feature Guide for EX9200 Switches In the example above, filter uses the statement, and so the pmff_bd_filter_2 port-mirror filter action uses the mirroring properties of the first port mirroring instance applied to the router (or switch) chassis at the...
Port Mirroring Feature Guide for EX9200 Switches Table 5: Application of Layer 2 Port Mirroring Firewall Filters on PE Routers and PE Switches Point of Application Scope of Mirroring Notes Configuration Details Ingress Customer-Facing Packets originating within a You can also configure...
Port Mirroring Feature Guide for EX9200 Switches NOTE: If you associate integrated routing and bridging (IRB) with the VLAN (or VPLS routing instance), and also configure within the VLAN (or VPLS routing instance) a forwarding table filter with the port-mirror port-mirror-instance action, then the IRB packet is mirrored as a Layer 2 packet.
Page 62
Port Mirroring Feature Guide for EX9200 Switches The value of the option can be , or family ethernet-switching vpls Enable configuration of a firewall filter pm-filter-name [edit firewall family family] user@host# edit filter pm-filter-name Enable configuration of a firewall filter term...
Page 64
Port Mirroring Feature Guide for EX9200 Switches Related Understanding Layer 2 Port Mirroring on page 3 Documentation Layer 2 Port Mirroring Firewall Filters Understanding Layer 2 Port Mirroring to Multiple Destinations Using Next-Hop Groups on page 68 Example: Layer 2 Port Mirroring at a Logical Interface...
Page 66
Port Mirroring Feature Guide for EX9200 Switches For a Fast Ethernet, Gigabit Ethernet, or Aggregated Ethernet interface, bind an 802.1Q VLAN tag ID to the logical interface: [edit interfaces interface-name unit logical-unit-number] user@host# set vlan-id number Enable specification of an input or output filter to be applied to Layer 2 packets that are part of bridging domain, Layer 2 switching cross-connects, or virtual private LAN service (VPLS).
Port Mirroring Feature Guide for EX9200 Switches Applying Layer 2 Port Mirroring to Traffic Forwarded or Flooded to a VLAN You can apply a Layer 2 port-mirroring firewall filter to traffic being forwarded or flooded to a VLAN. Only packets of the specified family type and forwarded or flooded to that VLAN are mirrored.
Port Mirroring Feature Guide for EX9200 Switches Applying Layer 2 Port Mirroring to Traffic Forwarded or Flooded to a VPLS Routing Instance You can apply a Layer 2 port-mirroring firewall filter to traffic being forwarded or flooded to a VPLS routing instance. Only packets of the specified family type and forwarded or flooded to that VPLS routing instance are mirrored.
Port Mirroring Feature Guide for EX9200 Switches Example: Layer 2 Port Mirroring at a Logical Interface The following steps describe an example in which the global port-mirroring instance and a port-mirroring firewall filter are used to configure Layer 2 port mirroring for the input to a logical interface.
Port Mirroring Feature Guide for EX9200 Switches flexible-vlan-tagging; encapsulation extended-vlan-bridge; unit 2 { vlan-tags outer 10 inner 20; family ethernet-switching; Packets received at logical interface ge-2/0/6.0 on VLAN example-bd-with-traffic evaluated by the port-mirroring firewall filter . The firewall example-bridge-pm-filter filter acts on the input traffic according to the filter actions configured in the firewall...
Port Mirroring Feature Guide for EX9200 Switches chassis { fpc 2 { port-mirror-instance inst1; Configure interface ge-2/2/9 for the VLANs, and configure interface ge-2/0/1 for port mirroring with the firewall filter: pm_filter_ccc [edit] interfaces { ge-2/2/9 { encapsulation ethernet-bridge; unit 0 { family ethernet-switching;...
Page 78
Port Mirroring Feature Guide for EX9200 Switches term pm { then port-mirror; Apply the aggregated Ethernet interfaces and port mirror instance to the chassis: [edit] chassis { aggregated-devices { ethernet { device-count 10; fpc 2 { port-mirror-instance pm_instance_1; Configure interfaces...
Port Mirroring Feature Guide for EX9200 Switches NOTE: When configuring a Layer 2 port-mirroring firewall filter, do not include the optional statement that specifies match conditions based on the from route source address. Omit this statement so that all packets are considered...
Port Mirroring Feature Guide for EX9200 Switches Understanding Layer 2 Port Mirroring to Multiple Destinations Using Next-Hop Groups On an MX Series router and on an EX Series switch, you can mirror traffic to multiple destinations by configuring next-hop groups in Layer 2 port-mirroring firewall filters applied to tunnel interfaces.
Page 86
Port Mirroring Feature Guide for EX9200 Switches For information about configuring firewall filter match conditions in general (including in a Layer 3 environment), see Firewall Filter Match Conditions Based on Numbers or Text Aliases, Firewall Filter Match Conditions Based on Bit-Field Values, Firewall Filter...
Port Mirroring Feature Guide for EX9200 Switches Defining a Next-Hop Group for Layer 2 Port Mirroring On MX Series routers and EX Series switches, you can mirror tunnel interface input traffic to multiple destinations. To this form of multipacket port mirroring, you specify two or...
Port Mirroring Feature Guide for EX9200 Switches Applying Layer 2 Port Mirroring to a Logical Interface You can apply a Layer 2 port-mirroring firewall filter to the input or to the output of a logical interface, including an aggregated Ethernet logical interface. Only packets of the address-type family specified by the filter action are mirrored.
Port Mirroring Feature Guide for EX9200 Switches Related Understanding Layer 2 Port Mirroring on page 3 Documentation Layer 2 Port Mirroring Firewall Filters Defining a Layer 2 Port-Mirroring Firewall Filter Applying Layer 2 Port Mirroring to Traffic Forwarded or Flooded to a Bridge Domain...
Layer 2 Port Mirroring to Remote Destination by Using Destination as VLAN You configure port mirroring on an EX9200 switch to send copies of traffic to an output destination, such as an interface, a routing-instance, or a VLAN; and for the input traffic, you can configure a firewall filter term with various match conditions and actions.
Port Mirroring Feature Guide for EX9200 Switches BEST PRACTICE: Mirror only necessary packets to reduce potential performance impact. We recommend that you: Disable port mirroring that you have configured when you are not using them. Specify individual interfaces as input rather than specifying all interfaces as input in a port mirroring configuration.
Layer 2 Port Mirroring to Remote Destination by Using Destination as VLAN on page 81 Example: Configuring Layer 2 Port Mirroring to Remote VLAN EX9200 switches enable you to configure mirroring to send copies of packets to either a local interface for local monitoring or to a VLAN for remote monitoring. You can use...
Page 100
Verification on page 89 Requirements This example uses the following hardware and software components: An EX9200 switch connected to another EX9200 switch Junos OS Release 13.2X50-D10 or later for EX Series switches Before you configure remote mirroring, be sure that: You have an understanding of mirroring concepts.
Page 102
Port Mirroring Feature Guide for EX9200 Switches set firewall family ethernet-switching filter watch-employee term employee-to-corp then accept set firewall family ethernet-switching filter watch-employee term employee-to-web from destination-port 80 set firewall family ethernet-switching filter watch-employee term employee-to-web then port-mirror-instance employee-web-monitor set interfaces ge-0/0/0 unit 0 family ethernet-switching filter input watch-employee...
Page 104
Port Mirroring Feature Guide for EX9200 Switches family ethernet-switching { filter watch-employee { term employee-to-corp { from { source-address { 192.0.2.16/28; destination-address { 192.0.2.16/28; then accept; term employee-to-web { from { destination-port 80; then port-mirror-instance employee-web-monitor; forwarding-options { analyzer employee-web-monitor {...
Page 108
Port Mirroring Feature Guide for EX9200 Switches Related Understanding Layer 2 Port Mirroring on page 3 Documentation Defining a Layer 2 Port-Mirroring Firewall Filter Applying Layer 2 Port Mirroring to Traffic Forwarded or Flooded to a Bridge Domain Applying Layer 2 Port Mirroring to Traffic Forwarded or Flooded to a VPLS Routing Instance...
Port Mirroring Feature Guide for EX9200 Switches Hierarchy level introduced in Junos OS Release 13.2X50-D10 for [edit vlans vlan-name] EX Series switches. Hierarchy level introduced in Junos OS Release [edit bridge-domains bridge-domain-name] 14.1 for MX Series routers. Description Configure traffic forwarding.
Port Mirroring Feature Guide for EX9200 Switches show chassis fabric fpcs List of Syntax Syntax on page 116 Syntax (MX Series Routers) on page 116 Syntax (MX2010 and MX2020 3D Universal Edge Routers) on page 116 Syntax (T4000 Core Router) on page 116...
Page 134
Port Mirroring Feature Guide for EX9200 Switches show chassis fabric fpcs (MX2020 Router) on page 130 show chassis fabric fpcs (MX2020 Router with MPC4E) on page 133 show chassis fabric fpcs (MX2020 Router with SFB2) on page 135 show chassis fabric fpcs (T320 Router) on page 138...
Page 158
Port Mirroring Feature Guide for EX9200 Switches Links ok SIB #4 Links ok PFE #1 SIB #0 Links ok SIB #1 Links ok SIB #2 Links ok SIB #3 Links ok SIB #4 Links ok FPC #5 PFE #0 SIB #0...
Page 164
Port Mirroring Feature Guide for EX9200 Switches Links ok SIB #3 Links ok SIB #4 Links ok PFE #1 SIB #0 Unused SIB #1 Links ok SIB #2 Links ok SIB #3 Links ok SIB #4 Links ok FPC #3...
Page 170
Port Mirroring Feature Guide for EX9200 Switches PFE #0 SIB #0 Links ok SIB #1 Links ok SIB #2 Links ok SIB #3 Links ok SIB #4 Links ok PFE #1 SIB #0 Links ok SIB #1 Links ok SIB #2...
Page 178
Port Mirroring Feature Guide for EX9200 Switches NOTE: On T4000 routers, when you include the enhanced-mode statement at the hierarchy level and reboot [edit chassis network-services] the system, only the T4000 Type 5 FPCs present on the router become online while the remaining FPCs are offline, and FPC misconfiguration alarms are generated.
Page 182
(MX240 Router) on page 173 show chassis fpc (MX480 Router) on page 173 show chassis fpc detail (EX9200 Switch) on page 173 show chassis fpc (MX480 Router) on page 174 show chassis fpc (MX480 Router with 100-Gigabit Ethernet CFP) on page 174...
Port Mirroring Feature Guide for EX9200 Switches Table 7: show chassis fpc Output Fields Field Name Field Description Level of Output Slot number and state. The state can be one of the following conditions: all levels Slot Slot State —Held in reset because of errors.
Page 186
Port Mirroring Feature Guide for EX9200 Switches Table 7: show chassis fpc Output Fields (continued) Field Name Field Description Level of Output I/O Manager version number, manufacturer, and part number. I/O Manager ASICs detail information Time when the Routing Engine detected that the FPC was running.
Page 188
Port Mirroring Feature Guide for EX9200 Switches Start time 2013-05-23 14:39:18 IST Uptime 1 hour, 20 minutes, 22 seconds show chassis fpc pic-status (MX104 Router) user@host> show chassis fpc pic-status Slot 0 Online Slot 1 Online PIC 0 Online 10x 1GE(LAN) -E...
Page 189
Interrupt DRAM (MB) Heap Buffer Empty Online 1024 Empty Empty Empty Empty show chassis fpc detail (EX9200 Switch) user@switch> show chassis fpc detail Slot 2 information: State Online Temperature Total CPU DRAM 2048 MB Total RLDRAM 331 MB Total DDR DRAM...
Page 190
Port Mirroring Feature Guide for EX9200 Switches State Online Temperature Total CPU DRAM 2048 MB Total RLDRAM 1036 MB Total DDR DRAM 6656 MB Start time: 2014-03-12 15:00:18 UTC Uptime: 1 hour, 39 minutes, 39 seconds Max Power Consumption 520 Watts show chassis fpc (MX480 Router) user@host>...
Page 192
Port Mirroring Feature Guide for EX9200 Switches show chassis fpc detail (MX480 Router with MPC4E) user@host> show chassis fpc detail Slot 2 information: State Online Temperature Total CPU DRAM 2048 MB Total RLDRAM 1036 MB Total DDR DRAM 11264 MB...
Page 194
Port Mirroring Feature Guide for EX9200 Switches Slot 8 information: State Online Temperature Total CPU DRAM 3584 MB Total XR2 291 MB Total DDR DRAM 24960 MB Start time: 2014-04-22 10:02:07 PDT Uptime: 1 hour, 23 minutes, 19 seconds Max Power Consumption...
Page 196
Port Mirroring Feature Guide for EX9200 Switches Max MIC0 Power Consumption 50 Watts Max MIC1 Power Consumption 50 Watts Max MPC Total Power Consumption 585 Watts show chassis fpc (MX2010 Routers) user@host> show chassis fpc Temp CPU Utilization (%) Memory...
Page 198
Port Mirroring Feature Guide for EX9200 Switches show chassis fpc (MX2020 Router with MPC4E) user@host> show chassis fpc Temp CPU Utilization (%) Memory Utilization (%) Slot State Total Interrupt DRAM (MB) Heap Buffer Online 2048 Empty Empty Empty Empty Empty...
Page 200
Port Mirroring Feature Guide for EX9200 Switches Max Power Consumption 520 Watts Slot 2 information: State Online Temperature Total CPU DRAM 2048 MB Total RLDRAM 1036 MB Total DDR DRAM 11264 MB Start time: 2014-04-22 23:33:34 PDT Uptime: 6 minutes, 9 seconds...
Page 208
Port Mirroring Feature Guide for EX9200 Switches Total SDRAM 1280 MB Start time 2010-10-04 20:06:46 PDT Uptime 1 hour, 32 minutes, 27 seconds lcc3-re0: -------------------------------------------------------------------------- Slot 2 information: State Online Temperature 38 degrees C / 100 degrees F Total CPU DRAM...
Page 210
Port Mirroring Feature Guide for EX9200 Switches State Online Temperature 49 degrees C / 120 degrees F Total CPU DRAM 2048 MB Total SRAM 64 MB Total SDRAM 1280 MB Start time 2010-10-04 21:12:52 PDT Uptime 32 minutes, 9 seconds...
Port Mirroring Feature Guide for EX9200 Switches Replace number with the following values depending on the LCC configuration: 0 through 3, when T640 routers are connected to a TX Matrix router in a routing matrix. 0 through 3, when T1600 routers are connected to a TX Matrix Plus router in a routing matrix.
Page 221
(EX4300 Switch) on page 214 show chassis hardware models (EX4500 Switch) on page 215 show chassis hardware detail (EX9200 Switch) on page 215 show chassis hardware (M7i Router) on page 216 show chassis hardware (M10 Router) on page 216...
Page 222
Port Mirroring Feature Guide for EX9200 Switches show chassis hardware (MX480 Router) on page 236 show chassis hardware (MX480 Router with Enhanced MX SCB) on page 236 show chassis hardware (MX480 Routers with MPC5E and Built-In OTN PIC) on page 236...
Page 224
Port Mirroring Feature Guide for EX9200 Switches show chassis hardware clei-models (PTX5000 Packet Transport Router with AC PSM and PDU) on page 373 show chassis hardware clei-models (PTX5000 Packet Transport Router with FPC2-PTX-P1A) on page 373 show chassis hardware detail (PTX5000 Packet Transport Router) on page 374...
Page 226
Port Mirroring Feature Guide for EX9200 Switches Table 9: show chassis hardware Output Fields (continued) Field Name Field Description Level of Output keyword only) Identification number that describes the FRU hardware. Assb ID extensive extensive Assembly ID keyword only) Version number of the FRU hardware.
Page 230
Port Mirroring Feature Guide for EX9200 Switches Fan Tray 0 FANTRAY-T-S Fan Tray 1 FANTRAY-T-S Fan Tray 2 FAN-REAR-TX-T640-S show chassis hardware (EX2300-C Switch) user@switch> show chassis hardware Hardware inventory: Item Version Part number Serial number Description Chassis HV0215410003 EX2300-C-12P...
Page 231
750-035700 GG0210271867 EX4500-40F-FB-C PIC 0 BUILTIN BUILTIN EX4500-40F-FB-C Power Supply 1 REV 01 740-029654 H884FS00JC09 EX4500-PWR1-AC-FB show chassis hardware detail (EX9200 Switch) user@switch> show chassis hardware Hardware inventory: Item Version Part number Serial number Description Chassis JN111DA44RFB EX9208 Midplane REV 05...
Page 234
Port Mirroring Feature Guide for EX9200 Switches Fan Tray 0 Front Upper Fan Tray Fan Tray 1 Front Middle Fan Tray Fan Tray 2 Front Bottom Fan Tray Fan Tray 3 Rear Fan Tray show chassis hardware models (M20 Router) user@host>...
Page 242
Port Mirroring Feature Guide for EX9200 Switches show chassis hardware (MX5 Router) user@host> show chassis hardware Hardware inventory: Item Version Part number Serial number Description Chassis E1368 MX5-T Midplane REV 01 711-038215 YF5288 MX5-T PEM 0 Rev 04 740-028288 VA01215...
Page 250
Port Mirroring Feature Guide for EX9200 Switches FPC 2 BUILTIN Fan Tray REV 02 711-049570 CAAX6538 PROTO-ASSEMBLY show chassis hardware (MX240 Router) user@host> show chassis hardware Hardware inventory: Item Version Part number Serial number Description Chassis JN10C7F7EAFC MX240 Midplane REV 01...
Page 252
Port Mirroring Feature Guide for EX9200 Switches show chassis hardware (MX480 Router) user@host> show chassis hardware Hardware inventory: Item Version Part number Serial number Description Chassis JN10C7F7FAFB MX480 Midplane REV 04 710-017414 TR2071 MX480 Midplane FPM Board REV 02 710-017254...
Page 294
Port Mirroring Feature Guide for EX9200 Switches Fan Tray 2 REV 2A 760-046960 ACAY0020 Fan Tray 3 REV 2A 760-046960 ACAY0021 show chassis hardware clei-models (MX2010 Routers) user@host > show chassis hardware clei-models Hardware inventory: Item Version Part number CLEI code...
Page 338
Port Mirroring Feature Guide for EX9200 Switches FPM Board REV 03 710-014974 ZR0639 Front Panel Display Rev 03 740-013110 QCS152250SX Power Distribution Module PEM 0 Rev 10 740-013683 QCS1512718W DC Power Entry Module PEM 1 Rev 10 740-013683 QCS1512702Y DC Power Entry Module...
Page 378
Port Mirroring Feature Guide for EX9200 Switches B Board REV 02 711-034979 EN1471 F2S SIB 3D Mezz Fan Tray 0 REV 10 760-024497 EH3313 Front Fan Tray Fan Tray 1 REV 10 760-024497 EH3290 Front Fan Tray Fan Tray 2...
Page 386
Port Mirroring Feature Guide for EX9200 Switches show chassis hardware interconnect-device (QFabric Systems) user@switch> show chassis hardware interconnect-device interconnect1 Hardware inventory: Item Version Part number Serial number Description Chassis REV 07 QFX_olive Midplane REV 07 750-021261 BH0208188289 QFX Midplane CB 0...
Page 390
Port Mirroring Feature Guide for EX9200 Switches show chassis hardware detail (PTX5000 Packet Transport Router) user@host> show chassis hardware detail Hardware inventory: Item Version Part number Serial number Description Chassis JN11D1FD7AJA PTX5000 Midplane REV 03 711-031896 ABAC5589 Midplane-8S REV 08...
Page 392
Port Mirroring Feature Guide for EX9200 Switches Hardware inventory: Item Version Part number Serial number Description Chassis JN1204FC0AJA PTX5000 Midplane REV 11 750-035893 ACAB8038 Midplane-8S REV 12 760-030647 BBBD5619 Front Panel Display PDU 0 Rev 04 740-048336 1GB93470043 High Capacity DC PDU...
Page 400
Port Mirroring Feature Guide for EX9200 Switches show chassis hardware extensive (ACX500 Router) user@host> show chassis hardware extensive Hardware inventory: Item Version Part number Serial number Description Chassis VJ0214510035 ACX500-AC Jedec Code: 0x7fb0 EEPROM Version: 0x02 S/N: VJ0214510035 Assembly ID:...
Page 404
Port Mirroring Feature Guide for EX9200 Switches Release Information Command introduced before Junos OS Release 7.4. Command introduced in Junos OS Release 9.0 for EX Series switches. Command introduced in Junos OS Release 11.1 for QFX Series. Command introduced in Junos OS Release 12.2 for ACX Series Universal Access Routers.
Page 406
Port Mirroring Feature Guide for EX9200 Switches switches, replace with 0 for built-in network interfaces and 1 for interfaces slot-number on uplink modules. For EX8208 and EX8216 switches, replace with 0. slot-number For the QFX3500, QFX3600, QFX5100, and OCX Series standalone switches , replace slot-number with 0.
Page 408
Port Mirroring Feature Guide for EX9200 Switches Table 10: show chassis pic Output Fields (continued) Field Name Field Description Status of the PIC. State is displayed only when a PIC is in the slot. State — PIC is online and running.
Page 412
Port Mirroring Feature Guide for EX9200 Switches PIC port information: Fiber Xcvr vendor Wave- Xcvr Port Cable type type Xcvr vendor part number length Firmware 100GBASE LR4 Oclaro Inc. TRB5E20FNF-LF150 1309 nm show chassis pic fpc-slot pic-slot (MX960 Router with MPC3E and 100-Gigabit DWDM OTN MIC) user@host>...
Port Mirroring Feature Guide for EX9200 Switches show forwarding-options port-mirroring Syntax show forwarding-options port-mirroring <terse | detail> <instance-name> Release Information Command introduced in Junos OS Release 9.6. Command introduced in Junos OS Release 12.3R2 for EX Series switches. Description Display current state of port-mirroring instances.
Port Mirroring Feature Guide for EX9200 Switches show firewall List of Syntax Syntax on page 416 Syntax (EX Series Switches) on page 416 Syntax show firewall <counter counter-name> <detail> <filter (filter-name | regex regular-expression)> <log> <logical-system (all | logical-system-name)> <terse>...
Port Mirroring Feature Guide for EX9200 Switches Table 12: show firewall Output Fields Field Name Field Description Name of a filter that has been configured with the statement at the hierarchy Filter filter [edit firewall] level. Except on EX Series switches:...
Page 436
Port Mirroring Feature Guide for EX9200 Switches Sample Output show firewall filter (MX Series Router and EX Series Switch) user@host> show firewall filter test Filter: test Counters: Name Bytes Packets Counter-1 Counter-2 Policers: Name Bytes Packets Policer-1 2770 show firewall filter (non MX Series Router and EX Series Switch) user@host>...
Page 438
Port Mirroring Feature Guide for EX9200 Switches Filter name Term name Policer name myfilter polcr-term-1 myfilter-polcr-1 inet-filter-ae ae-snmp policer-1 inet-filter-ae ae-ssh policer-2 Policer Counter Index 1: Bytes Packets Green: Yellow: Discard: Filter name Term name Policer name Policer Counter Index 2:...
Page 440
Port Mirroring Feature Guide for EX9200 Switches Table 13: show firewall log Output Fields (continued) Field Name Field Description Displays the name of a configured firewall filter or service filter Filter only if the packet hit the filter’s action in a kernel filter (in the control plane).
Port Mirroring Feature Guide for EX9200 Switches show forwarding-options port-mirroring Syntax show forwarding-options port-mirroring <terse | detail> <instance-name> Release Information Command introduced in Junos OS Release 9.6. Statement introduced in Junos OS Release 12.3R2 for EX Series switches. Hierarchy level introduced in Junos OS Release 13.2X50-D10...
Port Mirroring Feature Guide for EX9200 Switches show forwarding-options next-hop-group Syntax show forwarding-options next-hop-group <terse | brief | detail> <group-name> Release Information Command introduced in Junos OS Release 9.6. Command introduced in Junos OS Release 12.3R2 for EX Series switches.
Page 448
Port Mirroring Feature Guide for EX9200 Switches Members Interfaces: State ge-0/2/8.0 next-hop 192.0.2.10 ge-5/1/8.0 next-hop 203.0.113.10 ge-5/1/9.0 next-hop 198.51.100.10.10 Next-hop-group: nhg6 Type: inet6 State: up Number of members configured Number of members that are up Number of subgroups configured Number of subgroups that are up : 1...
Need help?
Do you have a question about the EX9200 and is the answer not in the manual?
Questions and answers