Juniper EX9214 Hardware Manual page 111

Ex series
Hide thumbs Also See for EX9214:
Table of Contents

Advertisement

Table 38: EX Series Switch Environmental Tolerances (continued)
Environment Tolerance
Switch or
device
Altitude
EX4600
No performance
degradation to
6,562 feet
(2000 meters)
EX6210
No performance
degradation up to
10,000 feet
(3048 meters)
EX8208
No performance
degradation up to
10,000 feet
(3048 meters)
EX8216
No performance
degradation up to
10,000 feet
(3048 meters)
EX9204
No performance
degradation up to
10,000 feet
(3048 meters)
EX9208
No performance
degradation up to
10,000 feet
(3048 meters)
Copyright © 2017, Juniper Networks, Inc.
Relative Humidity
Normal operation ensured in
the relative humidity range
5% through 90%,
noncondensing
Short-term operation
ensured in the relative
humidity range 5%
through 93%,
noncondensing
NOTE:
As defined in
NEBS GR-63-CORE, Issue
4, short-term events can
be up to 96 hours in
duration but not more
than 15 days per year.
Normal operation ensured in
the relative humidity range
10% through 85%
(noncondensing)
Normal operation ensured in
the relative humidity range
10% through 85%
(noncondensing)
Normal operation ensured in
the relative humidity range
10% through 85%
(noncondensing)
Normal operation ensured in
the relative humidity range
5% through 90%
(noncondensing)
Normal operation ensured in
the relative humidity range
5% through 90%
(noncondensing)
Chapter 6: Preparation Overview
Temperature
Normal operation ensured in
the temperature range 32° F
(0° C) through 113° F (45° C)
Nonoperating storage
temperature in shipping
container: –40° F (–40° C)
through 158° F (70° C)
Normal operation is ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
Normal operation is ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
Normal operation is ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
Normal operation is ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
Nonoperating storage
temperature in shipping
container: –40° F (–40° C) to
158° F (70° C)
Normal operation is ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
Nonoperating storage
temperature in shipping
container: –40° F (–40° C) to
158° F (70° C)
Seismic
Designed to comply
with Zone 4
earthquake
requirements per
NEBS GR-63-CORE,
Issue 4.
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Complies with Zone 4
earthquake
requirements as per
GR-63.
Complies with Zone 4
earthquake
requirements as per
GR-63.
87

Advertisement

Table of Contents