Troubleshooting Procedures; Troubleshooting The Cooling System In An Ex9200 Switch - Juniper EX9214 Hardware Manual

Ex series
Hide thumbs Also See for EX9214:
Table of Contents

Advertisement

CHAPTER 28

Troubleshooting Procedures

Troubleshooting the Cooling System in an EX9200 Switch

Problem
Solution
Related
Documentation
Copyright © 2017, Juniper Networks, Inc.
Troubleshooting the Cooling System in an EX9200 Switch on page 277
Troubleshooting Power Supplies in an EX9200 Switch on page 278
Troubleshooting Line Cards in EX9200 Switches on page 279
Troubleshooting Traffic Drops on EX9200-6QS Line Cards on page 281
Description: The fans in the fan tray are not functioning normally.
Follow these guidelines to troubleshoot the fans:
Check the fan LEDs and alarm LEDs on the craft interface.
If the major alarm LED on the craft interface glows, use the CLI to get information about
the source of an alarm condition:
user@switch> show chassis alarms
If the CLI output lists only one fan failure and the other fans are functioning normally,
the fan is most likely faulty and you must replace the fan tray.
Place your hand near the exhaust vents at the side of the chassis to determine whether
the fans are pushing air out of the chassis.
If a fan tray is removed, both a minor alarm and a major alarm occur.
The following conditions automatically cause the fans to run at full speed and also
trigger the indicated alarm:
A fan fails (major alarm).
The switch temperature exceeds the temperature warm threshold (minor alarm).
The temperature of the switch exceeds the temperature hot threshold (major alarm
and automatic shutdown of the power supplies).
Maintaining the Air Filter in EX9200 Switches on page 256
Maintaining the Fan Tray in EX9200 Switches on page 260