9.10 POWER-SELECTION OPERATION PESEL
This function is used when the circuit breaker is shared with other electrical
appliances. It limits the maximum currenl and power consumption to 100%,
75%, of 50% and can be implemented by POWER-SELECTION. The lower
percentage, the higher saving and also longer compressor lifetime.
Note:
● Due to the reason that POWER-SELECTION function limits the maximum
current, inadequate cooling or heating capacity may occur.
1. Press MENU button for enter menu setting and press TEMP. button to
select POWER-SEL.
2. Enter POWER-SEL setting by press MENU button again.
3. Select POWER-SEL level by press TEMP. button.
100%
75%
4. Confirm POWER-SEL level by press MENU button.
When feature had selected will return to menu selection display triangle mark
will blink
.
5. Leave from menu setting display by press EXIT button.
MANUAL DEFROST OPERATION
10
To defrosting the heat exchanger of the outdoor unit during Heating operation.
Press and hold
: for 5 seconds, then remote controller display
will show
as picture 1 for 2 seconds.
Blink only triangle
Blink only feature
50%
Blink only triangle
Feature already set.
1
DISPLAY LAMP BRIGHTNESS
11
ADJUSTMENT
To decrease the display lamp brightness or turn it off.
1. Press and hold
or
) is shown on remote controller LCD then release the button.
Rise
2. Press
or
Decrease
Remote
controller
LCD
Lamp illuminates full brightness.
Lamp illuminates 50% brightness.
Lamp illuminates 50% brightness and the
operation lamp is turned off.
All lamps are turned off.
● In the examples of
and
going off.
AUTO RESTART FUNCTION SETTING
12
This product is designed so that, after a power failure, it can restart
automatically in the same operating mode as before the power failure.
Information
The product is shipped with Auto Restart function in the ON position.
Turn it OFF if this function is not required.
How to turn OFF the Auto Restart Function
● Press and hold the [OPERATION] button on the indoor unit for 3 seconds
(3 beep sounds but OPERATION lamp does not blink).
How to turn ON the Auto Restart Function
● Press and hold the [OPERATION] button on the indoor unit for 3 seconds
(3 beep sounds and OPERATION lamp blink 5 time/sec for 5 seconds).
Note:
● In case of ON timer or OFF timer are set, AUTO RESTART OPERATION
does not activate.

SELF CLEANING OPERATION

13
(COOL AND DRY OPERATION ONLY)
To protect bad smell caused by the humidity in the indoor unit.
1. If the
button is pressed once during "Cool" or "Dry" mode,
the fan will continue to run for other 30 minutes, then it will turn off
automatically. This will reduce the moisture in the indoor unit.
2. To stop the unit immediately, press the
30 seconds.

TEMPORARY OPERATION

14
In case of the misplaced or discharged remote controller.
● Pressing the RESET button, the unit can start or
stop without using the remote controller.
● Operation mode is set on AUTOMATIC operation,
preset temperature is 24°C and fan operation is
automatic speed.
8
for 3 seconds until brightness level (
to adjust brightness in 4 levels.
Operation display
Brightness
All turned off
, the lamp illuminates for 5 seconds before
more 2 times within
OPERATION / RESET Button
,
,
EN
100%
50%
50%