Item
9. ECO
When pressing [ECO] button on the remote controller, a
Economic operation is performed.
operation
<Cooling operation>
This function operates the air conditioner with the difference
between the set and the room temperature as shown in the
following figure.
TA
+6.5
+6.0
+5.5
+5.0
+4.5
+4.0
+3.5
+3.0
+2.5
+2.0
+1.5
+1.0
+0.5
TSC
-0.5
-1.0
-2.0
1H
10. COMFORT
Cooling mode
SLEEP
• The preset temperature will increase as below.
• Press the [COMFORT SLEEP] button to
choose the operating hours. Repeat
pressing to select the hours.
(1hr, 3hr, 5hr or 9hr)
• If the [COMFORT SLEEP] button is pressed
again means cancel comfort sleep mode.
TA
+6.5
+6.0
+5.5
+5.0
+4.5
+4.0
+3.5
+3.0
+2.5
+2.0
+1.5
+1.0
+0.5
TSC
-0.5
-1.0
-2.0
1H
Operation flow and applicable data, etc.
2H
3H
4H
* 12 (DRY max - COOL min) /6 x 5 + COOL min
* 11 (DRY max - COOL min) /6 x 4 + COOL min
* 10 (DRY max - COOL min) /6 x 3 + COOL min
* 9 (DRY max - COOL min) /6 x 2 + COOL min
* 8 (DRY max - COOL min) /6 x 1 + COOL min
2H
3H
4H
* 12 (DRY max - COOL min) /6 x 5 + COOL min
* 11 (DRY max - COOL min) /6 x 4 + COOL min
* 10 (DRY max - COOL min) /6 x 3 + COOL min
* 9 (DRY max - COOL min) /6 x 2 + COOL min
* 8 (DRY max - COOL min) /6 x 1 + COOL min
Note : DRY max for calculation only.
<Cooling operation>
1) The control target temperature
increase 0.5ºC per hour up to 2ºC
starting from the set temperature
when ECO has been received.
2) The indoor fan speed is depend on
Zone Frequency
FAN
12
Dry Max
presetting and can change every
11
*12
speed after setting ECO operation.
10
*11
*10
9
3) The compressor speed is
8
*9
controlled as shown in the left
7
*8
6
figure.
5
4
3
2
Min
1
Hz
OFF
Time
The principles of comfort sleep mode are:
• Quietness for more comfortable.
When room temperature reach setting
temperature
• Save energy by changing room
temperature automatically.
• The air condition can shut down by itself
automatically.
Remarks:
Comfort sleep mode will not operate in
dry mode and fan only mode.
Zone Frequency
FAN
Dry Max
12
11
*12
10
*11
*10
9
8
*9
7
*8
6
5
4
3
2
Min
1
Hz
OFF
Time
- 31 -