CLI – Layer 2
automatically:
P330-N# set logout 20
Sessions will be automatically logged out after 20 minutes of
idle time.
Output Example:
To disable the automatic disconnection of idle sessions:
P330-N# set logout 0
Sessions will not be automatically logged out.

set timezone

Use the set timezone command to assign a timezone name and set the time
difference of your P330 relative to the Coordinated Universal Time (UTC/GMT).
The minutes parameter can only be set to 30.
The syntax for this command is:
set timezone <zone_name> <hours | hours:min>
Output Example:
set timezone GMT -3:30
Timezone set to 'GMT', offset from UTC is -3:30 hours
Note: If you wish to define a name which includes spaces, you must enclose the
entire name in quotation marks, e.g. "new york".
set time protocol
Use the set time protocol command to set the protocol for use in the system as either
SNTP protocol or TIME protocol.
The syntax for this command is:
set time protocol
Output Example:
P330-N# set time protocol sntp-protocol
The protocol has been set to SNTP protocol
Output Example:
P330-N#
88
[sntp-protocol|time-protocol]
set time protocol time-protocol