OBTAINING DIAGNOSTIC INFORMATION
Running Far-End Tests
7-24
When you choose
View Far-End Tests
can choose from the selections in the following table:
Table 7-10: Far-End Tests Menu Options
Menu Option
Run Remote Video-Audio
Loopback
Run Remote CSU Loopback
Stop Test
a. This item appears only when your system has an internal CSU
daughter board installed.
Running Remote Video-Audio Loopback
With this test, you can verify the quality of the image and the audio
being sent to the far-end site.
To run a remote loopback:
1. Make any adjustments to the system video and audio levels.
2. From the Diagnostics menu, choose View Far-End Tests .
3. Choose Run Remote Video-Audio Loopback .
from the Diagnostics menu, you
Definition
Displays the near-end video image
on your full screen with
accompanying audio after
looping the signals through the
far-end electronics module.
Refer to page 7-24.
a
Displays the near-end video image
on your full screen after looping
the signal through both near- and
far-end CSUs.
Refer to page 7-25.
Halts the test in progress, and
displays the Far-End Tests menu.