CONFIGURING PORTS

Table 6-3: Set Control Port B Screen Options

Select Type
Enter Baud Rate
Select Parity
Select RTS/DTR
6-4
Option
ConÞgures the mode of operation for the control
port, as described in Table 6-4.
ConÞgures the rate at which information passes
through the control port:
Determines the number of data bits in each word of
information that passes through the control port as
well as the parity checking of a received word:
This option can be set for Network Managers and
asynchronous devices.
(Request to Send/Data Terminal Ready)
ConÞgures the hardware ßow control exerted by
the system:
This option can be set for asynchronous devices.
Description
The Network Manager port type has a default
setting of 1200.
Dataconferencing application ports have a
default setting of 19200.
8 bits, None (default)
8 bits, Odd
8 bits, Even
7 bits, None
7 bits, Even
used when your terminal device does
Ignored,
not observe the RTS/DTR ßow control
protocol.
used when your terminal device
Not Ignored,
observes the RTS/DTR ßow control protocol.