Accessory; Electric Motor - JLG Toucan 12E Service And Maintenance Manual

Personal lifts
Hide thumbs Also See for Toucan 12E:
Table of Contents

Advertisement

6-7 Accessory

DTC
Help Message
FUNCTIONS
An obstacle has been detected by the soft
672
CUTOUT - SOFT
touch device (if equipped).
TOUCH
DETECTED
FUNCTIONS
This DTC does not apply to the Toucan
673
CUTOUT - GATE
12E.
OPEN DETECTED

7-7 Electric Motor

DTC
Help Message
LEFT DRIVE
The Slave Power Module has detected an
7712
MOTOR – OPEN
open circuit on one or more motor phase
CIRCUIT
connections.
RIGHT DRIVE
The Master Power Module has detected
7715
MOTOR OPEN
an open circuit on one or more motor
CIRCUIT
phase connections.
LEFT DRIVE
The Slave Power Module detects that the
7718
MOTOR ROTA-
left motor is rotating in the direction oppo-
TION OPPOSITE
site of the commanded direction.
CONTROL
RIGHT DRIVE
The Master Power Module detects that
7720
MOTOR ROTA-
the right motor is rotating in the direction
TION OPPOSITE
opposite of the commanded direction.
CONTROL
MASTER MOD-
The power capacitor bank of the power
7721
ULE CAPACITOR
module is not charging properly at
BANK FAULT
startup.
31210149
Condition Producting DTC
Condition Producting DTC
– JLG Lift –
SECTION 10 - DIAGNOSTIC TROUBLE CODES
Control system Response or
Machine Condition
• Clear the obstacle.
• Ensure ANALYZER-
>MACHINE SETUP->SOFT
TOUCH is set to 0 if not
installed.
• Ensure ANALYZER-
>MACHINE SETUP->GATE
is set to 0 (Not Installed).
Control system Response or
Machine Condition
• Check the harness for signs
of damage
• Replace the Slave Power
Module
• Check the harness for signs
of damage
• Replace the Master Power
Module
• Check the harness for
proper installation
• Check the motor phase for
proper installation
• Check that the motor is con-
nected to the correct con-
troller
• Check the harness for
proper installation
• Check the motor phase for
proper installation
• Check that the motor is con-
nected to the correct con-
troller
• Ensure that no external
device is connected to the
batteries. Refer to a qualified
JLG mechanic to know the
approved options on the
machine.
• Check battery, power cables
and connections.
Corrective Action/Operational
Requirement for Function
Movement and/or to Clear Fault
• Clear the obstacle.
Refer problem to a qualified JLG
mechanic.
Refer problem to a qualified JLG
mechanic.
Corrective Action/Operational
Requirement for Function
Movement and/or to Clear Fault
Refer problem to a qualified JLG
mechanic.
Refer problem to a qualified JLG
mechanic.
Refer problem to a qualified JLG
mechanic.
Refer problem to a qualified JLG
mechanic.
Refer problem to a qualified JLG
mechanic.
10-33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Toucan 12e plusToucan 32eToucan 12e

Table of Contents