Danfoss VLT AAF006 Operating Instructions Manual page 57

Active filter
Hide thumbs Also See for VLT AAF006:
Table of Contents

Advertisement

Applications and Basic Prog...
15-31 Alarm Log: Value
Array [10]
Range:
0
[-32767 - 32767 ] View an extra description of the error.
*
15-32 Alarm Log: Time
Array [10]
Range:
0 s
[0 - 2147483647 s] View the time when the logged event
*
6
6
6.8.5 15-4* Unit Identification
Parameters containing read-only information about the
hardware and software configuration of the active filter.
15-40 FC Type
Range:
0
[0 - 6] View the active filter type. The readout is identical
*
to the type code, characters 1–6.
15-41 Power Section
Range:
0
[0 - 20] View the active filter type. The readout is identical
*
15-42 Voltage
Range:
0
[0 - 20] View the active filter type. The readout is identical
*
15-43 Software Version
Range:
0
[0 - 5 ] View the combined SW version (or 'package
*
15-44 Ordered Typecode String
Range:
0
[0 - 40 ] View the typecode string used for re-ordering the
*
15-45 Actual Typecode String
Range:
0
[0 - 40 ]
*
15-46 Unit Ordering No
Range:
0 N/A
[0 - 0 N/A] View the 8-digit ordering number used for
*
54
Function:
This parameter is mostly used in
combination with alarm 38 internal fault.
Function:
occurred. Time is measured in seconds
from unit start-up.
Function:
Function:
to the type code, characters 7–10.
Function:
to the type code, characters 11–12.
Function:
version') consisting of power SW and control SW.
Function:
active filter in its original configuration.
Function:
View the actual type code string.
Function:
re-ordering the active filter in its original
configuration.
Danfoss A/S © 09/2014 All rights reserved.
Operating Instructions
15-47 Power Card Ordering No
Range:
0
[0 - 8 ]
*
15-48 LCP Id No
Range:
0
[0 - 20 ]
*
15-49 SW ID Control Card
Range:
0
[0 - 20 ]
*
15-50 SW ID Power Card
Range:
0
[0 - 20 ]
*
15-51 Unit Serial Number
Range:
0 N/A
*
15-53 Power Card Serial Number
Range:
0
[0 - 19 ]
*
6.8.6 15-6* Option Ident.
This read-only parameter group contains information about
the hardware and software configuration of the options
installed in slots A, B, C0 and C1.
15-60 Option Mounted
Array [8]
Range:
0
[0 - 30 ]
*
15-61 Option SW Version
Array [8]
Range:
0
[0 - 20 ]
*
15-62 Option Ordering No
Array [8]
Range:
0
[0 - 8 ] Shows the ordering number for the installed
*
15-63 Option Serial No
Array [8]
Range:
0
[0 - 18 ]
*
Function:
View the power card ordering number.
Function:
View the LCP ID number.
Function:
View the control card software version number.
Function:
View the power card software version number.
Function:
[0 - 0 N/A]
View the active filter serial number.
Function:
View the power card serial number.
Function:
View the installed option type.
Function:
View the installed option software version.
Function:
options.
Function:
View the installed option serial number.