Allen-Bradley PowerFlex 755T Installation Instructions Manual page 37

Powerflex 750-series products with totalforce control
Hide thumbs Also See for PowerFlex 755T:
Table of Contents

Advertisement

Debris Plug
M12 Bolt
Lock Washer
M12 Nut
M12
Anchor Bolt
Structural Steel System
Enclosures can be mounted to structural steel that is anchored to concrete and
meet the following specifications and minimum dimensions.
• Material: ASTM A-36 / ASME SA36, or equivalent
Figure 12 - Structural Steel Beam Cross-sections
Wide Flange Beam
d
b
Table 6 - Steel Beam Dimensions
Style
Depth (d)
mm (in.)
Wide Flange Beam
100 (4.0)
Channel Beam
100 (4.0)
Structural Steel Mounting Configurations
Enclosures can be mounted directly to structural steel beams by using M12-
1.75 screws threaded into the threaded corner holes. The enclosures must be
secured to the anchor bolts in all four corners by using M12 nuts and lock
washers. Secure the steel beam to the concrete floor by using M12 (0.5 in.)
anchor bolts.
Figure 13 - Structural Steel Mounting Cross-section
Rockwell Automation Publication 750-IN100B-EN-P - July 2017
tf
d
tw
Width (b)
mm (in.)
100 (4.0)
43 (1.7)
Prepare for Installation
Chapter 3
Channel Beam
tw
b
Thickness (tw)
Flange (tf)
mm (in.)
mm (in.)
7.6 (0.3)
10.2 (0.4)
7.6 (0.3)
7.6 (0.3)
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerflex 755tlPowerflex 755trPowerflex 755tm

Table of Contents