Allen-Bradley PowerFlex 755T Installation Instructions Manual page 153

Powerflex 750-series products with totalforce control
Hide thumbs Also See for PowerFlex 755T:
Table of Contents

Advertisement

Table 28 - 11-Series I/O Module TB1 Wiring Examples (continued)
Input/Output
Connection Example
Digital Output
Internal supply
20-750-1133C-1R2T
P3
Digital Output
External supply
20-750-1133C-1R2T
PLC TB
+24V
24VC
T0
TC
T1
Main Control Board TB1
11-Series I/O Module TB2
3
3
P8
1
1
+24V
Common
OR
PLC
1756-1B16
IN-0
IN-1
IN-2
IN-3
IN-4
IN-5
IN-6
+24VDC
IN-7
GND-0
GND-0
Common
IN-8
IN-9
IN-10
IN-11
IN-12
IN-13
IN14
IN-15
GND-1
GND-1
11-Series I/O Module TB2
Rockwell Automation Publication 750-IN100B-EN-P - July 2017
Required Parameter Changes
• Set Selection
Port nn:20 [TO0 Sel] (11-Series I/O Module) = Port 10/11:354 [Motor Side Sts 1], bit 7 =
Faulted
• View Results
Port nn:5 [Dig Out Sts] (11-Series I/O Module)
• Set Selection
Port nn:20 [TO0 Sel] (11-Series I/O Module) = Port 10/11:354 [Motor Side Sts 1], bit 7 =
Faulted
• View Results
T0
Port nn:5 [Dig Out Sts] (11-Series I/O Module)
TC
T1
T0
TC
T1
I/O Wiring
Chapter 6
153

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerflex 755tlPowerflex 755trPowerflex 755tm

Table of Contents