* J3: Drive roller, J4: 2nd transfer facing roller, J6: Tension roller, J7: Idling roller
Fully clean up the toner and such adhering to the roller with alcohol when the transfer belt
cleaning blade is replaced, since an image failure may occur if there is any dirt remaining on the
roller. Also, remove dust and toner scattering adhering to the inside of the transfer belt unit in
order to keep rollers clean.
* J4: 2nd transfer facing roller
Apply Floil (GE-334C) all around the shaft of the 2nd transfer facing roller, which contacts the
grounding plate inside the 2nd transfer facing roller rear holder.
* J8: Transfer belt cleaning blade
Handling precautions
Pay attention to the following points as the cleaning blade life is determined by the condition
of its edge.
-
Do not allow hard objects to hit or rub against blade edge.
-
Do not rub the edge with a cloth or soft pad.
-
Do not leave oil (or fingerprints, etc.) on the edge.
-
Do not apply solvents such as paint thinner to the blade.
-
Do not allow paper fibers or dirt to contact the blade edge.
-
Do not place the blade near a heat source.
Cleaning procedure
Clean the blade edge with a cloth moistened with water and squeezed lightly.