3. Remove the FG harness ASSY 6 [A] ( x 5; S M3x6).
4. Remove the main PCB [B] from main frame L [C].
• When replacing the main PCB [B], refer to "Adjustments and Updating of Settings, Required
After Parts Replacement".
• After disconnecting flat cable(s), check that each cable is not damaged at its end or short-
circuited.
• When connecting flat cable(s), do not insert them at an angle. After insertion, check that the
cables are not at an angle.
PS PCB Unit/Fan 40
1. Side Cover R/Link Stopper (
p.39)
Main Body
4