Wsw01 (Dial Pulse Setting) - Ricoh HL-F1 Field Service Manual

Machine code: h558
Table of Contents

Advertisement

5. Service Maintenance
WSW43
WSW44
WSW45
WSW46
WSW47
WSW48
WSW49
WSW50
5
WSW51

WSW01 (Dial pulse setting)

Selector No.
1
2
3
4
5
6
162
Function setting 21
Speeding up scanning-1
Speeding up scanning-2
Monitor of power ON/OFF state and parallel port kept
at high
Switching between high- and full-speed USB
USB setup latency
End-of-copying beep and print in black
SDAA settings
Function setting 16
Function
Dial pulse generation mode
Break time length in pulse dialing
Inter-digit pause
p.200
p.201
p.201
p.201
p.201
p.201
p.201
p.202
p.202
Setting and Specifications
No. 1 2
0 0 : N
0 1 : N+1
1 0 : 10-N
1 1 : N
No. 3 4
0 0 : 60 ms
0 1 : 67 ms
1 0 : 40 ms (for 16 PPS)
1 1 : 64 ms (at 106-ms intervals)
No. 5 6
0 0 : 800 ms
0 1 : 850 ms
1 0 : 950 ms
1 1 : 600 ms