Wsw29 (Function Setting 7); Wsw30 (Function Setting 8); Wsw31 (Function Setting 9) - Ricoh HL-F1 Field Service Manual

Machine code: h558
Table of Contents

Advertisement

5. Service Maintenance
4 to 6
7
8
5
• Selectors 1 through 6: Transmission level of DTMF high-/low-band frequency signal
These selectors are intended for the manufacturer who tests the machine for the Standard. Never
access them.

WSW29 (Function setting 7)

Not used.

WSW30 (Function setting 8)

Not used.

WSW31 (Function setting 9)

Selector No.
1
2
3
4
190
Transmission level of DTMF low-band
frequency signal
Not used.
Function
Not used.
Default reduction rate for failure of
automatic reduction during recording
Not used.
Do not disturb this selector.
No. 4 5 6
0 0 0 : 0 dB
0 0 1 : +1 dB
0 1 0 : +2 dB
0 1 1 : +3 dB
1 0 0 : 0 dB
1 0 1 : -1 dB
1 1 0 : -2 dB
1 1 1 : -3 dB
-
Setting and Specifications
-
0: 100% 1: 70%
-
-